Model G0746/G0749 (Mfg. Since 3/13)
-27-
Lubricating Lathe
GEARBOXES MUST
BE FILLED WITH OIL!
MACHINE MAY NOT BE
SHIPPED WITH OIL!
Requires Oil
Before Operation
or Warranty Will
Be Void.
the headstock, gearbox, and apron oil reservoirs
must have the proper amount of oil in them before
the lathe can be operated.
damage caused to the bearings and gears from
running the lathe without oil in the reservoirs
will not be covered under warranty. refer to the
Lubrication section, beginning on page 67, for
checking and adding oil.
in addition to the reservoirs, we also recommend
that you lubricate all other points on the machine
at this time. to do this, follow the steps provided in
the maintenance schedule on
page 66.
Note: If this lathe was shipped with oil in the res-
ervoirs, do not change that oil until after the
Test
Run and Spindle Break-In procedures.
Adding coolant
add the coolant of your choice now. For detailed
instructions on where the coolant tank is located
and how to add fluid, refer to
coolant System
Service on page 72.
power connection
Before the machine can be connected to the
power source, an electrical circuit and connection
device must be prepared according to the circuit
requirements on the
page 18, and the machine
must be completely setup and installed in its per-
manent location.
once the lathe is connected to the power supply,
the disconnect switch that is installed by the elec-
trician (as recommended) is the primary means
for disconnecting or connecting the machine to
the power source.
Note About phase converters: Due to the
startup load from this machine, we do not recom-
mend using a static phase converter to create
3-phase power—as it can quickly decrease the
life of electrical components on this machine. If
you must use a phase converter, only use a rotary
phase converter. Only connect the manufactured
leg or "wild wire" to the L3 terminal (see loca-
tion in
Figure 24 on Page 28). The L3 terminal
can handle power fluctuation because it is wired
directly to the motor.
Electrocution or fire
may occur if machine is
ungrounded, incorrectly
connected to power, or
connected to an undersized
circuit. use an electrician
or a qualified service
personnel to ensure a safe
power connection.