Model G0768/G0769 (Mfd. Since 8/15)
-75-
Column Ways (G0769)
Lube Type .. Model SB1365 or ISO 68 Equivalent
Lube Amount ........................................Thin Coat
Lubrication Frequency ................................. Daily
Regular lubrication will ensure your milling head-
stock performs at its highest potential.
Regularly
wipe table and column ways with recommended
lubrication, then move components back and
forth several times to ensure smooth movements
(see
Figure 134).
Quill Rack
Lube Type ..Model T23964 or NLGI#2 Equivalent
Lube Amount ........................................Thin Coat
Lubrication Frequency ......... 90 hrs. of Operation
Move quill all the way down to gain full access to
quill rack (see
Figure 136), lock the quill in place,
then clean teeth with mineral spirits, shop rags,
and a brush.
Quill Outside Surface
Lube Type .. Model SB1365 or ISO 68 Equivalent
Lube Amount ........................................Thin Coat
Lubrication Frequency ................................. Daily
Without disturbing grease on quill rack, clean out-
side smooth surface of quill (see
Figure 135) with
mineral spirits and shop rags.
When dry, apply thin coat of lubricant to smooth
surface, then move spindle up and down to evenly
distribute oil.
Figure 134. Z-axis way lubrication location.
Z-Axis Ways
(1 of 2)
Figure 135. Outside surface of quill.
Quill Outside
Surface
When dry, use a brush to apply a thin coat of
grease to teeth, then raise/lower the quill several
times to evenly distribute grease.
Note: Re-apply oil that may have been removed
during the cleaning process to the quill surface
around the rack.
Figure 136. Quill rack location.
Rack