-20-
Model G1163/G1163P (Mfg. Since 9/12)
SECTION 6: MAINTENANCE
Always disconnect power
to the machine before
performing maintenance.
failure to do this may
result in serious person-
al injury.
For optimum performance from your machine,
follow this maintenance schedule and refer to any
specific instructions given in this section.
daily Check:
•
loose mounting bolts.
•
Worn switch.
•
Worn or damaged wires.
•
Full collection bag.
•
any other unsafe condition.
Schedule
Since all bearings are shielded and permanently
lubricated, simply leave them alone until they
need to be replaced. Do not lubricate them.
Lubrication
Impeller Tightening
DiSCoNNECt DuSt CollECtoR FRoM
poWER
BEFoRE
attEMptiNG
thiS
pRoCEDuRE!
periodically check the impeller to make sure it is
tight on the motor shaft. any unusual vibration
or noise may be an indication the impeller has
loosened. a set screw and a left-hand cap screw
secure the impeller to the shaft. these can be
accessed through the inlet cover, as shown in
figure 20. tighten the fasteners as needed.
figure
20
. impeller screw locations.
Cap Screw
Set Screw
Always wear a respirator
and safety glasses when
emptying the dust collection
bag on the dust collector.
Sawdust may cause allergic
reactions or respiratory
problems.
always empty the collection bag on a regular
basis. Emptying the collection bag allows the
machine to operate at a much higher level of effi-
ciency. always wear the appropriate respirator or
dust mask and safety glasses when emptying the
collection bag. Small dust particles can escape
the bag during emptying, causing them to become
airborne and easily inhaled. this microscopic air-
borne dust is extremely unhealthy to breathe and
can cause serious health problems.
Bag Cleaning
Summary of Contents for G1163