G5045 10'' Bench
-17-
Figure 19.
45° check.
3.
Adjust the blade angle until the blade con-
tacts the square evenly.
4.
Advance the collar until it makes contact
with the bracket .
Figure 20.
5.
Line up and fasen the pointer.
6.
Reduce the blade tilt angle, then return it to
the 45° position. Re-check with your
square.
7.
Re-adjust, if necessary.
Table Parallelism
The G5045 table is factory-aligned. In the unlike-
ly event furthere adjustment is needed, a quick
inspection checks table parallelism:
1.
Place your miter gauge (set at 90°) in its
slot, even with the front of the blade. Place
a square between it and the side of the
blade. See
Figure 21
.
2
. Choose a tooth on the blade. close to the
gauge. Mark the tooth with a felt tip pen.
Bring marked tooth
1
⁄
2
" above the table top.
Set square to touch the marked tooth.
3.
Slide the miter gauge toward the back of the
saw until the square is at the trailing end of
the blade. Keep square in place.
4.
Turn the blade so marked tooth is
1
⁄
2
" above
the table at the back end of the blade. The
square should touch the marked tooth.
Figure 21.
Testing for table parallelism.
2.
Place the 45° angle of your square against
the blade. If the blade and square are not
contacting evenly, Loosen the pointer as
shown in
Figure 19
.
Figure 20.
45 degree stop collar.