H3372 3 HP Air Compressor
-15
-
After every 300 hours or 3 months of
regular operation, perform the following
maintenance items:
•
Change the compressor motor oil.
Use compressor oil or a non-deter-
gent 30 weight oil.
•
Rinse the air filter foam element in
water.
•
Check for air leaks and correct as
needed.
•
Clean the cylinder head fins for prop-
er cooling.
•
Check for loose bolts or fittings.
When storing your air compressor fol-
low these guidelines:
1.
Set the ON/OFF button to OFF.
2.
Turn the regulator counter-clockwise
to set the delivery pressure to zero.
3.
Disconnect air tools or accessories.
4.
Pull the safety drain valve ring to
bleed excess pressure from tank. The
pressure gauge for the tank should
read 15-20 PSI.
5.
Drain water from the tank by opening
the drain valve on the bottom of the
tank.
6.
Close the drain valve when all the
water has been released.
7.
Store the air compressor in its normal
operating position in a cool protected
area.
Every 300 Hours
Storage
Like all power tools, there is danger
associated with operating this
equipment. Accidents are frequently
caused by lack of familiarity or fail-
ure to pay attention. Use this
machine with respect and caution to
lessen the possibility of operator
injury. If normal safety precautions
are overlooked or ignored, serious
personal injury many occur.
NOTICE
Water will condense in the air com-
pressor tank. Water left in the tank
can cause the tank to weaken and
corrode, increasing the risk of tank
rupture.