-26-
Model T32335 (Mfd. Since 11/20)
Air leaks will cause low air output and increase
the time the compressor must run.
Checking for Leaks
Checking for Leaks
1. Disconnect tool and hose from compressor.
2. Turn ON compressor and allow tank to fill
until cut-out pressure is reached (115 PSI).
3. DISCONNECT MACHINE FROM POWER!
4. Listen for sound of air to find possible leak.
— If you do not hear air escaping, and pres-
sure in tank does not change, there is no
leak.
— If you hear air escaping, or pressure in
tank drops even with safety relief valve
and drain valve closed, proceed to
Step 5.
5. Spray suspected air leak with soap and water
solution and look for air bubbles.
— If no bubbles form, repeat at different
location.
— If bubbles form, proceed to
Fixing Leaks.
Fixing Leaks
2. Use safety relief valve to reduce tank pres-
sure to less than 10 PSI.
3. Open drain valve to relieve any remaining air.
4. Remove fitting or valve that is leaking and
clean.
5. Apply Teflon tape or pipe dope to clean
threads, then re-install part.
Note: If a fitting or valve continues to leak
after preceding steps, replace part.
Item Needed
Qty
Teflon Tape or Pipe Dope .................. As Needed
Releasing air through drain valve can
be extremely loud. Protect hearing with
ANSI-approved hearing protection while
performing following step.
To fix leaks:
1. DISCONNECT MACHINE FROM POWER!
Summary of Contents for QUIET Series