Model T32337 (Mfd. Since 05/22)
-23-
Base
Cap
Some water may accumulate in the tank depend-
ing on usage and humidity. Drain water from the
tank daily to increase the lifespan of the compres-
sor and air tools and to prevent tank corrosion.
Draining Tank
Figure 24. Drain valve handle open.
To drain tank:
1. DISCONNECT MACHINE FROM POWER!
2. Use safety relief valve to reduce tank pres-
sure to less than 10 PSI.
3. Open drain valve (see Figure 24) to drain
condensation from tank.
Releasing air through safety relief valve
can be extremely loud. Protect hearing
with ANSI-approved hearing protection in
following step.
The air filters help prevent impurities and dust
from entering the compressor and reduce noise.
Dirty filters will result in a less efficient system and
could become a fire hazard.
Checking Air Filters
To check air filters:
1. DISCONNECT MACHINE FROM POWER!
Releasing air through safety relief valve
can be extremely loud. Protect hearing
with ANSI-approved hearing protection in
following step.
2. Use safety relief valve to reduce tank pres-
sure to less than 10 PSI.
3. While holding base of filter assembly in place,
turn filter cap counterclockwise to remove
cap (see
Figure 25).
Figure 25. Air filter assembly components.
— If filter is fairly clean and there has not
been a drop in efficiency of compressor,
replace cap. No replacement is required.
— If filter is dirty or clogged, or there has
been a drop in efficiency of compressor,
replace cap. Proceed to
Step 4.
4. Repeat Step 3 for second filter assembly.
5. Replace old filter(s) with new filter element(s)
(refer to Part #2 in
Parts beginning on
Page 34).