-16-
Model T32338 (Mfd. Since 12/20)
Do not touch compressor
head or discharge line
during use or immediately
after compressor is active.
These hot parts may cause
burns.
8. After running compressor for 20 minutes,
move pressure switch to OFF position to turn
machine
OFF.
9. Turn drain valve handle to closed position.
10. Turn machine ON and observe tank pressure
gauge (see
Figure 13) while tanks fill.
Figure 13. Location of tank pressure gauge.
Tank
Pressure Gauge
— If motor and pump turn
OFF when tank
pressure reaches 125 PSI, then safety
feature of check valve is working correctly.
Proceed to
Step 11.
— If motor and pump do not turn
OFF when
tank pressure reaches 125 PSI, then
immediately turn
OFF machine and dis-
connect it from power. Safety feature of
check valve is NOT working properly and
must be replaced before further using
machine.
11. Turn machine OFF and slowly pull safety
relief valve ring to bleed pressure from tanks
(see
Figure 14).
— If safety relief valve bleeds pressure from
tanks, and air stops leaking when pressure
is released, then safety feature of safety
relief valve is working correctly. Proceed
to
Step 12.
— If safety relief valve is stuck or leaks after
releasing pressure, immediately turn
OFF
machine and disconnect it from power.
Safety relief valve must be replaced before
further using machine.
12. Open drain valve to drain moisture from
tanks.
13. Repeat Step 1 to check oil level.
Note:
Change oil after first 8 hours of use
(see
Lubrication on Page 25).
Congratulations! Test Run is complete.
Figure 14. Location of safety relief valve.
Safety Relief
Valve
Releasing air through safety relief valve
can be extremely loud. Protect hearing
with ANSI-approved hearing protection in
following step.