Model T32338 (Mfd. Since 12/20)
-37-
READ ELECTRICAL SAFETY
ON PAGE 36!
Neutral
Hot
Ground
120 VAC
5-15 Plug
SUNNY SP-204
PRESSURE
SWITCH
LINE
MOTOR
GND
Motor Overload
Reset Button
MOTOR 120V
RONG FENG
20A
Start Capacitor
300MFD 125V
+ LINE LOAD −
Run Capacitor
50uF 250V
WARNING!
SHOCK HAZARD!
Disconnect power
before working on
wiring.
GND
Wiring
Diagram
Figure 45. Pressure switch wiring.
Figure 46. Motor wiring.