Model T32339 (Mfd. Since 03/21)
-13-
The voltage conversion MUST be performed by
an electrician or qualified service personnel.
The voltage conversion procedure consists of
rewiring the motor and installing the correct plug.
A wiring diagram is provided on
Page 39 for your
reference.
IMPORTANT: If the diagram included on the
motor conflicts with the one on
Page 39, the
motor may have changed since the manual was
printed. Use the diagram included on the motor
instead.
To convert voltage to 230V:
1. Remove (2) bolts shown in Figure 8 to
remove motor wiring cover.
Converting Voltage
to 230V
Items Needed
Qty
Flat Head Screwdriver
1
⁄
4
" or Wrench
1
⁄
4
" ........... 1
Phillips Head Screwdriver #2 ............................ 1
NEMA 6-15 Plug ................................................ 1
Figure 8. Location of motor wiring cover and
bolts.
3. Move white motor wire from terminal 4 to ter-
minal 2 (see
Figures 9–10).
LINE
MOTOR
LEFOO LF10-4H
PRESSURE
SWITCH
GND
Neutral
Hot
Ground
115 VAC
5-15 Plug
MOTOR 115V/230V
Run
Capacitor
30uF 370V
Start
Capacitor
189-227uF 165V
1
4
2
6
Figure 9. Motor wired for 115V power supply.
6-15 Plug
Hot
Hot
Ground
230
VAC
G
LINE
MOTOR
LEFOO LF10-4H
PRESSURE
SWITCH
GND
MOTOR 115V/230V
Run
Capacitor
30uF 370V
Start
Capacitor
189-227uF 165V
(As Recommended)
1
4
2
6
Figure 10. Motor wired for 230V power supply.
2. Move brown motor wire from terminal 2 to
terminal 6 (see
Figures 9–10).
Note: Terminal 6 is an insulating pocket. You
can use wire nut or crimp instead, if desired.
4. Install motor wiring cover.
Motor Wires
Motor Wires
Summary of Contents for T32339