Model T32339 (Mfd. Since 03/21)
-25-
The oil level in the Model T32339 should be
checked daily to prevent overheating and dam-
age to the compressor. Change the oil every 500
hours of use.
Lubrication
To check oil level:
1. Check oil sight glass (see Figure 32). Oil
level should be kept between bottom and top
of red circle.
Checking Oil Level
Some water may accumulate in the tank depend-
ing on usage and humidity. Drain water from the
tank daily to increase the lifespan of the compres-
sor and air tools and to prevent tank corrosion.
Draining Tank
Figure 30. Drain valve handle open.
Drain Valve
Handle
To drain tank:
1. DISCONNECT MACHINE FROM POWER!
2. Use safety relief valve to reduce tank pres-
sure to less than 10 PSI.
3. Open drain valve (see Figure 30) to drain
condensation from tank.
Releasing air through safety relief valve
can be extremely loud. Protect hearing
with ANSI-approved hearing protection in
following step.
Figure 32. Location of oil sight glass and oil fill
plug.
Oil Sight
Glass
Oil Fill
Plug
Item Needed
Qty
Model T28041 (or SAE 30 Equiv.) ..... As Needed
T28041—Primrose Air Compressor Oil
This oil is a blend of the highest quality solvent
refined, paraffinic, and naphthenic petroleum min-
eral oils and additives which prevent rust and
oxidation. It's formulated for clean, trouble-free
air compressor lubrication and effective control of
carbon deposits for longer life. 1 quart size.
Figure 31. T28041 236 Primrose Plus Air
Compressor Oil.
— If oil level is between top and bottom of red
circle, no additional oil is needed.
Summary of Contents for T32339