OM-SSB-G
7
OM-SSB-3G/5G/10GF
6. Factory-Stacked Units
This section is applicable only if you are
installing factory-stacked units.
Installing stacked steamers is similar
to installing a single unit. The steamers
are stacked and assembled at the factory
and delivered with the water connections and
drain hoses required for a single point
connection.
A.
Water Connection
The same water supply connection
is used for both units. At the water
inlet valve a
3
/
4
inch female NH connector
(gardenhosetype)isusedforthewatersupply.
B.
Electrical Supply Connection
Separate electrical connections will be
required for each steamer to be stacked. Each
steamer unit must have it’s own branch
circuit protection.
C.
Gas Connection
A single gas connection is required for
both steamers. Gas supply must be
adequate under all conditions as listed on
page 6.
D.
Drain Connection
Steamers must be leveled front to back, and
pitched to the front (maximum
1
/
4
inch) by
adjusting the bullet feet on the cabinet or
stand base.
For all factory-stacked SSB steamers,
a 2
1
/
2
inch ID hose is attached to the
unit drain. It must be rated for boiling water.
7.
Counter-Mounted Units
This section is applicable if the steamer will
be mounted to a counter. All four edges of the
bottom of the steamer must be sealed
with RTV to the counter if the 4 inch
legs are not used. Counter must be made
of a noncombustible material such as
metal or tile.