Automatic Greasing System
Twin-3
System test
25
Da
te
of
is
sue
:
Ja
nu
ar
y 2
0
1
1
EG1703P03
3.2
S
ingle greasing cycle test
In order to check the system, perform a single greasing cycle as follows:
1.
With the test push-button at pump:
a.
Switch ignition ON;
b.
Push the test push-button at pump for 2-6 seconds.
The system will operate a single greasing cycle.
During the operation the green LED at Twin-3 display or signal lamp at the duty mode
push-button will flash slowly (2-sec. on / 2-sec. off).
A code “T1” and a running-decimal-dot will be indicating its pump, pressure retaining
and pressure decrease phase at Twin-3 display;
c.
When the single greasing cycle is finished, the pump reverts to automatic mode and
shows its active duty mode at Twin-3 display or signal lamp at the duty mode push-
button will go off.
2.
With the switch-button at Twin-3 display:
a.
Switch ignition ON;
b.
Push the switch-button at least for 5 seconds.
Accordingly, the 3-digit display starts flashing;
c.
Push the switch-button repeatedly until code “T1” shows;
d.
Leave the code “T1” flashing until the code comes on.
The system will operate a single greasing cycle. (See also next alinea).
During the operation the green LED at Twin-3 display will flash slowly (2-sec. on / 2-sec.
off).
A code “T1” and a running-decimal-dot will be indicating its pump, pressure retaining
and pressure decrease phase at Twin-3 display;
e.
When the single greasing cycle is finished, the pump reverts to automatic mode and
shows its active duty mode and green LED comes on.
The single cycle test ends after the pressure decrease phase or when the ignition is switched OFF.
When the ignition is switched ON again the program will always begin with the pause phase of the
cycle that has just been interrupted.
ATTENTION
Remember that a single cycle test only tests one of the primary grease lines. To test the other
primary grease line, a second single cycle test has to be performed.