background image

2

GB

Application

Can be used in conjunction with:

• Pressurised storage heaters

• Thermally controlled instantaneous heaters

• Hydraulically controlled instantaneous heaters

Operation with unpressurised storage heaters (= open water 
heaters) is not possible.

Technical data

• Flow pressure

- min.

0.5 bar

- recommended 

1 - 5 bar

• Operating pressure max.

10 bar

• Test pressure

16 bar

A pressure reducing valve must be fitted in the supply line if 
static pressures exceed 5 bar to satisfy noise level ratings.

Avoid major pressure differences between hot and cold water 
supply.

• Temperature

Hot water inlet:

max. 70 °C

Recommended (energy saving):

60 °C

• Water connection

hot - left

cold - right

Note:

This fitting can be combined with head and hand shower sets 
by using a 3-way diverter.

Important note:

Never install shut-off valves in the outlet pipe (mixed 
water) downstream of any built-in mixer.

Installation

Prepare the wall for the installation.

• Prepare the holes for the single lever mixer and slots for the 

pipes.

Align single lever mixer using fitting template and fit,

 

see fold-out page I, Figs. [1] and [2].

• Permissible tolerances are given on the dimensional 

drawing.

• The arrow on the fitting template must point upwards.

• To align place a spirit level on the fitting template, see 

Fig. [1].

• The housing is provided with pre-drilled holes (B) to facilitate 

mounting the fitting to the wall.

• The finished surface of the wall (C) must lie within the 

area (X) of the fitting template, see Fig. [2].

• The cold water supply must be connected on the right, hot 

water supply on the left.

Connect pipes.

Open cold and hot-water supply and check connections 
for water-tightness.

Flush piping system prior and after installation of fitting 
thoroughly (Consider EN 806)! 

Plaster and tile the wall, see Fig. [3].

Attention! You must tile directly to the fitting template!

Do 

not

 remove the fitting template before final installation.

Final installation

Remove fitting template, 

see Fig. [4].

Install escutcheon and lever, 

see Figs. [5].

Seal the escutcheon with silicone.

Check mixer for correct operation,

 see Fig. [6].

Function of automatic diverter (D),

 see Fig. [6].

Pulling the lever will release water delivery.

On the bath mixer, water will always emerge from the lower 
outlet first (e.g. bath outlet).

Pressing diverter (D) shuts off the flow of water to the bath and 
delivers water to the shower outlet.

When the mixer is closed, the diverter is released 
automatically so that when the mixer is opened again, water 
will always emerge from the lower outlet first (e.g. bath outlet).

Care

Dear Customer,

We want to ensure that you get long-lasting satisfaction and 
pleasure from your 

GROHE

 fitting. Therefore, please read the 

following care instructions because damage to the surface and 
underlying material resulting from improper treatment is not 
covered by warranty.

Do not use any abrasive sponges or scouring agents for 
cleaning. We also advise you not to use cleaning agents 
containing solvent or acid, limescale removers, household 
vinegar and cleaning agents with acetic acid in them. They are 
aggressive to the surface - and will leave your fitting dull and 
scratched. As the formulations of commercially available 
cleaning agents frequently change, we cannot guarantee they 
will provide the gentle care our fitting deserves.

Clean the fitting with a little soap and a moist cloth only, then 
simply rinse off and wipe dry. You can avoid lime spots by 
drying the fitting each time it is used. If lime deposits do occur, 
remove them with 

GrohClean

, our environment-friendly 

cleaning liquid. 

GrohClean

 is specially formulated to clean the 

surface of our fittings gently. 

GrohClean

 is available from your 

supplier.

www.divapor.com

Summary of Contents for BauClassic 29 047

Page 1: ...DESIGN ENGINEERING GROHE GERMANY www grohe com BauClassic 99 177 331 ÄM 240105 08 18 29 047 29 048 w w w d i v a p o r c o m ...

Page 2: ...I 1 B 2 C X 3 4 5 6 D w w w d i v a p o r c o m ...

Page 3: ...侧 热水进水管必须接左侧 连接水管 打开冷热水进水管 检查接头是否存在渗漏情况 安装龙头前后务必彻底冲洗管道系统 请遵照 EN 806 用石膏和瓷砖镶贴墙面 如图 3 所示 注意 必须将瓷砖直接镶贴到龙头底盘上 在完成最终安装之前 请勿拆下龙头底盘 最终安装 拆下龙头底盘 如图 4 所示 安装面盖和手柄 如图 5 所示 用硅树脂密封面盖 检查混合龙头是否可以正确操作 如图 6 所示 打开自动分水器 D 如图 6 所示 拉动手柄将开始供水 对于浴缸龙头 水始终先从较低的出水口流出 即浴缸出 水嘴 按下分水器 D 将关闭流向浴缸的水流 而将水输送到淋浴出 水口 混合龙头关闭时 分水器会自动复位 这样 当混合龙头再次 打开时 水将始终从较低的出水口流出 即浴缸出水嘴 保养 尊敬的客户 我们希望确保您能长期对 GROHE 龙头的使用感到满意和愉快 因此 请阅读以下保养说明 因为由于处理不当而造成的...

Page 4: ... tile the wall see Fig 3 Attention You must tile directly to the fitting template Do not remove the fitting template before final installation Final installation Remove fitting template see Fig 4 Install escutcheon and lever see Figs 5 Seal the escutcheon with silicone Check mixer for correct operation see Fig 6 Function of automatic diverter D see Fig 6 Pulling the lever will release water delive...

Page 5: ... an die Einbauschablone verfliesen Einbauschablone nicht vor der Fertiginstallation demontieren Fertiginstallation Einbauschablone entfernen siehe Abb 4 Rosette und Hebel montieren Abb 5 Den Rosettenbereich mit Silikon abdichten Funktion der Batterie prüfen Abb 6 Funktion der automatischen Umstellung D siehe Abb 6 Durch Ziehen des Hebels wird die Wasserzufuhr freigegeben Bei der Wannenbatterie tri...

Page 6: ...2 6616354 grohe grohe ee LV 372 6616354 grohe grohe ee MAL info malaysia grohe com MX 01800 8391200 pregunta grohe com N 47 22 072070 grohe grohe no NL 31 79 3680133 vragen nl grohe com NZ technicalenquiries paterson trading co nz P 351 234 529620 commercial pt grohe com PL 48 22 5432640 biuro grohe com pl RI 0 800 1 046743 customercare indonesia asia lixil com RO 40 21 2125050 info ro grohe com R...

Reviews: