The boiling water storage heater with filter system may only 

be operated together with an original GROHE Red

®

 

 boiling 

water fitting.

Safety notes

GROHE Red

®

 

 boiling water storage heater:

This device is 

not

 intended for use 

by persons (including children) with 
physical, sensory or mental impairments 
or a lack of experience or knowledge 
in using devices of this type.

Children must be supervised to ensure 
that they do not play with the device.

Danger due to electric shock. Avoid 
damaged power supply cables. In the 
case of damage, the boiling water 
storage heater must be replaced by the 
manufacturer or its customer service 
department or an equally qualified person.

• The boiling water storage heater must be connected to 

a permanent power supply with earth wire.

• Installation may only be performed in frost-free rooms.

• The boiling water storage heater is only suitable for indoor use.

• The boiling water storage heater must be placed in an 

upright position. 

• The boiling water storage heater and plug must 

not

 be 

directly or indirectly sprayed with water when cleaning.

The boiling water storage heater must not be opened.

If the boiling water storage heater is to be drained, the safety 
assembly of the boiling water storage heater must be removed. 
Invert the boiling water storage heater and allow the water to 
run out. 

However, we strongly advise against draining the boiling 
water storage heater. There is a significant risk of 
damaging the boiling water storage heater.

Technical specifications

Boiling water storage heater electrical data:

• Connection:

Wall socket with earth wire,

protected with a 16 A fuse

• Voltage supply: 

220V AC / 50Hz

• Power consumption: 

1,900 W

• Standby power loss (switched on): 

15 W

• Standby power loss (switched off): 

 1 W

• Type of protection:

IPX4

Electrical installation

Electrical installation work must 
be performed only by a qualified 
electrician. This work must be carried 
out in accordance with the regulations 
to IEC 60364 -7-701 (corresponding 
to VDE 0100 Part 701) as well as all 
national and local regulations.

• Extension cables are 

not

 permitted between the electrical 

socket and boiling water storage heater connection.

Installation

Installation see page I and II.

Install storage heater taking into consideration the 
available hose lengths.

Do 

not 

connect voltage supply 

yet

.

Filling storage heater with water,

 see Figs. [2a/b] and [3a/b].

1. Open shut-off valve (A) at safety assembly, see detail, 

Fig. [2a/b]. 

2. Pull button (B1) on handle (B) of fitting outward and turn the 

handle anti-clockwise.

3. Fill the storage heater until water comes out of the spout of 

the fitting.

4. Connect voltage supply via mains plug (C), see Fig. [3a/b].

5. Press and hold button (D) on storage heater for at least 2 

seconds to switch on the storage heater. The red indicator 
lamp (D1) indicates that the storage heater is switched on.

Service

If the problem cannot be rectified, disconnect the mains plug 
to shut off the voltage supply. Note down the serial number 
of the storage heater on the rear of the device and get in touch 
with GROHE Customer Service or contact the GROHE 
Service Hotline under 

TechnicalSupport-HQ@grohe.com

.

Disposal

This category of device does 

not

 belong in the 

domestic waste, but must be disposed of 
separately in accordance with the relevant local 
national regulations.

The date of installation must be noted on the 
maintenance sticker and affixed at a visible location 
on the storage heater.

Summary of Contents for RED 40 701

Page 1: ...SLO 19 LT 24 I 5 FIN 10 H 15 HR 20 RO 25 DESIGN ENGINEERING GROHE GERMANY www grohe com 40 701 4L 40 700 CN 40 702 IND 8L GROHE RED 99 0226 131 ÄM 234106 03 15 CN 1 NL 6 PL 11 P 16 BG 21 CN 26 GB 2 S 7 UAE 12 TR 17 EST 22 UA 27 F 3 DK 8 GR 13 SK 18 LV 23 RUS 28 E 4 N 9 CZ 14 SLO 19 LT 24 I 5 FIN 10 H 15 HR 20 RO 25 ...

Page 2: ...I Please pass these instructions on to the end user of the fitting 请向本产品的用户提供这些说明 A 2a 19mm 19mm 19mm B1 B 24mm 1a D1 D 3a C ...

Page 3: ...II 1b 24mm 40 701 2b A B B1 3b D1 D C 2sec ...

Page 4: ... V AC 50 Hz 耗电量 1 900 W 待机功耗 打开 15 W 待机功耗 关闭 1 W 防护类型 IPX4 泄压阀的安全安装要求 泄压 泄压阀型号 SGB330 适用范围 10 bar 借用集成的音量控制 免维护 电气安装 电气安装工作只能由具有资质的电工执行 进行此项工作时 必须遵守 IEC 60364 7 701 对应于 VDE 0100 第 701 部分 的规定 以及国家 地区和当地 的所有规定 请勿在电气插座与沸水蓄热热水器的连接之间使用延长线 安装 安装请参阅第 I 和 II 安装蓄热热水器时需要考虑软管的有效长度 此时尚不能连接电源 给蓄热热水器加水 如图 2a b 及 3a b 所示 1 打开安全装置 A 上的截止阀 详情参见图 2a b 2 向外拉动龙头手柄 B 上的按钮 B1 并逆时针旋转手柄 3 给蓄热热水器加水 直到有水从龙头的出水嘴流出 4 通过主插头 C...

Page 5: ...a 16 A fuse Voltage supply 220V AC 50Hz Power consumption 1 900 W Standby power loss switched on 15 W Standby power loss switched off 1 W Type of protection IPX4 Electrical installation Electrical installation work must be performed only by a qualified electrician This work must be carried out in accordance with the regulations to IEC 60364 7 701 corresponding to VDE 0100 Part 701 as well as all n...

Page 6: ...30 info grohe co jp KZ 7 727 311 07 39 info cac grohe com LT 372 6616354 grohe grohe ee LV 372 6616354 grohe grohe ee MAL 1 800 80 6570 info singapore grohe com N 47 22 072070 grohe grohe no NL 31 79 3680133 vragen nl grohe com NZ 09 373 4324 P 351 234 529620 commercial pt grohe com PL 48 22 5432640 biuro grohe com pl RI 62 21 2358 4751 info singapore grohe com RO 40 21 2125050 info ro grohe com R...