Auxiliary Input connections

The inputs are supervised and may optionally be used with line resistors 

for fault detection.

Input 

switch

1K

1K

GND   

In +

1

Out NO

Com

Out NC

1

Normally Closed Contact
Common
Normally Open

The Auxiliary output relays off er volt free contacts and may be used to 

connect to low voltage systems such as barriers or turnstiles, provided 

the voltage across the contacts does not exceed 30V and current does 

not exceed 3A.

Input switch

GND   

In +

1

Contacts Only (no fault detection)

Supervised (short/open circuit detect)

Auxiliary Output connections

Inputs

1-8

Outputs

1-8

Power 

out

The Aux input is pulled to 5V by the Blade using the equivalent 

circuit shown below

Connections

Page 2

Power supply

12Vdc power supply 

for connecting 

associated devices.

+

Power Out

12 Vdc

0V

+12V

OUT

OUT

Supervised (short/open circuit detect)

Tamper 

switch

1K

1K

2K2

Input 

switch

GND   

In +

1

Supervised (short/open circuit detect)