Introduction 

SAVE THESE INSTRUCTIONS 

Please read and save this manual 

Thank you for selecting this uninterruptible power system (UPS). It provides you with a 
perfect protection for connected equipment. The manual is a guide to install and use the UPS. 
It includes important safety instructions for operation and correct installation of the UPS. If 
you should have any problems with the UPS, please refer to this manual before calling 
customer service. 

Please save or recycle the packaging materials 

The UPS‘s shipping materials are designed with great care to provide protection within 

delivery. These materials are invaluable if you ever have to return the UPS for service. 
Damage happened during transit is not covered under the warranty. 

Intelligent microprocessor control 

The product is an advanced line-interactive UPS based on microprocessor control. This 
means that it operates with the newest technology, high performance and powerful function.   

The line-interactive UPS is an intelligent protector and provides pure, reliable AC power to 
the critical loads - protecting them from utility power blackout, swells, sags, surges and 
interference. The loads could include sensitively medical instruments, computers, 
telecommunication systems, and industrially automatic equipment. Under power normal 
condition, the line-interactive design enables the system to adjust and filter power 
fluctuations continuously and automatically.    In the event of power failure, it can provide 
immediately back-up power from the batteries without any interruption. Complete 
transference will be achieved within 4m seconds, with no interruption.   

Beside this, when the utility power is connected, the charger would work automatically even 
under power switch is OFF. Furthermore, in order to save the battery energy, UPS can be set 
to turn it off under backup mode if none of the connected loads is operating. 

Advanced battery management 

The visual and audible indications of the UPS present the battery’s status including capacity 

degree and battery condition. Self-test function let UPS detect a weak battery before it is put 
into service. The UPS normally perform a self-test at power up and manual self-test 
condition. Self-test function can be conducted manually with the ON/TEST switch at any 
time. 

Advanced monitoring software 

The line-interactive UPS and UPSMON series monitoring software (optional kits) make 
your computer operate intelligent and provide you with the ability of perfect protection of 
your critical devices. The software is available for most operation systems and is supplied 
with a communication cable that connects to the UPS.

Summary of Contents for 700D

Page 1: ...I Manuale d uso User s manual Groups 700D ...

Page 2: ...occare e cortocircuitare i terminali di batteria L arco elettrico e l energia liberata può provocare gravi ustioni e shock da energia Quando si opera sulle batterie seguire le seguenti precauzioni rimuovere tutti gli oggetti metallici usare utensili con impugnatura isolante indossare guanti e stivali di gomma Non toccare con utensili o oggetti metallici i terminali di batteria Togliere la rete ele...

Page 3: ...3 4 Tacitazione allarme 3 5 Test di batteria in sicurezza 4 Allarme 4 1 Allarme lento funzionamento da batteria 4 2 Allarme rapido batteria scarica 4 3 Allarme continuo sovraccarico 5 Installazione software e porta interfaccia 5 1 Dati generali del software 5 2 Installazione del software 5 3 Connessione al cavo interfaccia 5 4 Caratteristiche del software UPSMON 6 Manutenzione e stoccaggio 6 1 Man...

Page 4: ... batterie Premendo il pulsante fino ad udire un bip si accendere o spegne l UPS E possibile eseguire il battery test con la rete elettrica presente tenendo premuto il pulsante meno di 1 secondo questa procedura verifica l efficienza delle batterie In funzionamento da batteria per tacitare l UPS premere il pulsante per almeno 1 sec Funzionamento da rete led verde Il led è acceso se la rete di ingre...

Page 5: ...ta di fusibile per la protezione dell UPS e dei carichi collegati USCITE PROTETTE Queste prese permettono di alimentare le utenze in continuità Se il valore della tensione di alimentazione dell UPS supera i limiti funzionali si inserisce l A V R che stabilizza la tensione al carico Se la tensione di alimentazione manca o è fuori tolleranza l UPS si stacca dalla rete elettrica e funziona da batteri...

Page 6: ... UPS in modo programmato di aver uno storico di funzionamento etc Attenzione collegare l UPS al computer utilizzando il cavo USB in dotazione 2 3 Collegamento alla rete elettrica Usare il cavo di alimentazione in dotazione per alimentare l UPS dalla rete elettrica verificando che il valore della stessa sia corretto 230 Vac 50 60Hz 2 4 Carica della batteria L UPS carica la batteria anche quando è s...

Page 7: ...ere eseguita in presenza di rete elettrica Premendo il pulsante di ON per alcuni secondi fino alla tacitazione del segnale acustico è possibile disattivare la funzione green mode Quindi anche in presenza di carico nullo o inferiore al 10 della potenza nominale l UPS rimarrà acceso In tale caso l UPS scaricherà completamente tutta l energia delle batterie 3 3 Spegnimento Premere il pulsante OFF per...

Page 8: ...LOAD In questo caso il suono emesso dall UPS è continuo e se la condizione persiste la macchina si spegnerà dopo alcuni secondi 5 Software e porta di interfacciamento 5 1 Software di monitoraggio Il software UPSMON consente di monitorare le molteplici funzioni dell UPS e provvede anche ad effettuare lo shut down del computer nel caso di mancanza della rete elettrica Inoltre è possibile ottenere un...

Page 9: ...il benvenuto di windows Welcome quindi seguire le istruzioni riportate Fare click su Next Fig 5 3 Fig 5 3 3 Selezionare il percorso dove installare il programma seguendo le istruzioni riportate Fare click su Next Fig 5 4 Fig 5 4 ...

Page 10: ...i mancanza rete elettrica Chiusura dei file aperti MS OFFICE prima che le batterie siano esaurite Corretta chiusura del sistema operativo Spegnimento dell UPS per preservare l energia delle batterie 5 5 Come usare il software UPSMON Dopo aver completato l installazione del software UPSMON si può avviare il programma ciccando sull icona presente nella barra strumenti del computer fig 5 5 Fig 5 5 il...

Page 11: ...e batterie dell UPS prima stoccarlo Scollegare tutti gli accessori pulire l UPS e riporlo nell imballo originale 6 3 Stoccaggio a lungo termine oltre 3 mesi Eseguire le operazioni al punto 6 2 Ricaricare le batterie dell UPS collegandolo alla rete elettrica ogni 6 mesi se la temperatura di conservazione è compresa tra 15 e 30 C 3 mesi se la temperatura di conservazione è compresa tra 30 e 45 C 7 S...

Page 12: ...te l ups quindi l operazione è particolarmente pericolosa perché vi sono parti in tensione anche senza rete elettrica con ups spento e batteria scollegata Pertanto la persona che si appresta alla sostituzione di batteria deve essere un tecnico qualificato e addestrato Appendice A ricerca guasti PROBLEMA POSSIBILE CAUSA SOLUZIONE UPS non si accende Led non si accendono e non si sente nessun suono b...

Page 13: ...rica Ricaricare le batterie per 24 ore consecutive L UPS è in sovraccarico Rimuovere il carico eccedente Le batterie sono esauste per l avvicinarsi del limite di vita Sostituire la batteria Il carica batterie non funziona bene Contattare l assistenza per una verifica L autonomia è 4 min con carico vicino a 0 E attiva la funzione green mode Se il carico è inferiore a 30W disattivare la funzione Gre...

Page 14: ...e eccede al 130 Corto circuito in uscita L UPS si spegne immediatamente o si aprono le protezioni verso la rete elettrica Batterie Tipo Ermetiche al piombo Tempo di ricarica 6 ore al 90 della capacità Protezione Automatica per eccessiva scarica Autonomia a seconda della potenza assorbita Caratteristic he fisiche Peso Kg 6 3 Dimensioni l x p x h mm 105 x 334 x 168 Allarmi Funzionamento da batteria ...

Page 15: ...c CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles Wear rubber gloves and boots Do not lay tools or metal parts on top of batteries Disconnect charging source prior to connecting or disconnecting battery terminals Se...

Page 16: ...vanced monitoring software V 1 Presentation 4 Front Panel 4 Rear Panel 7 2 Installation 6 2 1 Placement 6 2 2 Connect Computer Interface optional 6 2 3 Connect to Utility 6 2 4 Charge the battery 6 2 5 Connect the loads 6 3 Operation 7 3 1 Switch on with Green Mode Function 7 3 2 Switch on with Disabled Green Mode Function 7 3 3 Switch off 7 3 4 Silence 7 3 5 Self test function 7 4 Alarm 8 4 1 BAC...

Page 17: ...tware 8 5 2 Installing software 8 5 3 Connecting interface cable 10 5 4 The characteristics of software UPSMON 10 6 Maintenance and storage 11 6 1 Maintenance 11 6 2 Storage conditions 15 6 3 To extend the storage 15 Appendix A Troubleshooting Errore Il segnalibro non è definito Appendix B Specifications I ...

Page 18: ...s telecommunication systems and industrially automatic equipment Under power normal condition the line interactive design enables the system to adjust and filter power fluctuations continuously and automatically In the event of power failure it can provide immediately back up power from the batteries without any interruption Complete transference will be achieved within 4m seconds with no interrup...

Page 19: ...r 3 High grade battery charger to prolong battery s life and fully charge the battery 4 With actual overload protection both in line and battery mode Front Panel LCD type ON OFF TEST SILENCE button No matter the UPS plugged in or not Press the ON OFF TEST SILENCE button till the beep stop to turn on or to turn off the UPS When UPS is working under AC mode it also activates the UPS s self test by p...

Page 20: ... the battery needs to be replaced or the charger of UPS is fail to function When this Red LED flashes rapidly it indicates the UPS is over loaded Battery level bar It indicates the battery capacity and battery status When the battery capacity is low it becomes dim when the battery needs to be replaced or the charger of UPS is fail to function indicators on all the bar flash Output Voltage This dig...

Page 21: ...age of utility power should match with the UPS For example the rating voltage of UPS is 110V 220V the input utility power should be the same as 110V 220V INPUT CIRCUIT BREAKER FUSE It trips when the connected loads exceed the protected receptacle s capacity UPS SURGE PROTECTED OUTLETS When utility power is normal the UPS outlets are powered by utility power with AVR function Any higher or lower ut...

Page 22: ... computer interface connection CAUTION Use only factory supplied or authorized UPS monitoring cable 2 3 Connect to Utility The input power cord needs to connect the rear inlet socket of the UPS and plug into a socket on the wall Please notice the voltage of utility power should match with the UPS For example the rating voltage of UPS is 110V 220V the input utility power should be the same as 110V ...

Page 23: ...tch on with Disabled Green Mode Function When utility input is connected to the UPS press ON button and keep pressing until the Bi Bi Bi beeps stopped to turn on the UPS After that connect the electrical cords of the equipments that will be used such as Notebook computer and LCD monitor to the rear panel of UPS If the load is lighter than 30W please also refer this function to avoid any inconvenie...

Page 24: ...of battery becomes to lower level about 20 30 The UPS beeps rapidly until the UPS shuts down from battery exhaustion or returns to LINE mode operation ATTENTION The alarm of the batteries caused by low voltage beeps every 0 5 second ATTENTION The rapid alarm under LOW BATTERY condition cannot be muted 4 3 OVER LOAD continuous alarm When the UPS is working under overload condition the connected loa...

Page 25: ...uter OS compatible solutions 5 2 Installing software To perform monitoring functions you must install UPSMON series software accompanied with the UPS Please do the following steps to complete installation of UPSMON series software 5 Insert the UPSMON CD into your CD ROM drive The installation program should start automatically and installation menu appear as shown in Fig 5 1 Please select the oper...

Page 26: ... to complete installation of the software 5 3 Connecting interface cable A series of interface kits is available for operation systems that provide UPS monitoring Each interface kit includes the special interface cable required to convert status signals from the UPS into signals which individual operating system recognizes The interface cable at UPS side must be connected to REMOTE PORT at compute...

Page 27: ...ome computers are equipped with a special connector to link with the communication port In addition special plug in cord may be needed Some computers may need special UPS monitoring software Contact your dealer for the details on the various interface Kits 5 5 How to Use Software UPSMON After you have completed installation of the software UPSMON you can launch the software by clicking on the icon...

Page 28: ...tion intake open 6 1 6 Avoid direct sunlight rain and high humidity 6 1 7 Stay away from fire and extremely hot location 6 1 8 Do not stack materials on top of the unit 6 1 9 The unit should not be exposed to corrosive air 6 1 10 The normal operating temperature is 0 30 6 2 Storage conditions Store the UPS covered and upright in a cool and dry location with its battery fully charged Before storing...

Page 29: ... battery the unit contains no user serviceable parts Repairs should be performed only by factory trained service personnel CAUTION A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects 2 Use tools with insulated handles CAUTION Do not dispose of batteries i...

Page 30: ... connection between the UPS input outlet and utility power Fuse melted or circuit breaker tripped Replace fuse or reset circuit breaker you can find a spare fuse for UPS at inlet of UPS The battery s indicator is lit Buzzer keeps beeping The UPS is overloaded Remove less needed equipment Available time of the batteries is too short Battery not fully charged Keep UPS ON for over 24 hours to recharg...

Page 31: ...erload protection UPS automatic shutdown if overload exceeds 110 of nominal at 60 seconds and 130 at 3 seconds Short Circuit UPS output cut off immediately or input open protection Battery Type Sealed Maintenance free lead acid Typical Recharge Time 6 hours to 90 of full capacity Protection Auto discharge protection Back up Time a PC with 15 monitor Relative to output power Physical Net Weight Kg ...

Reviews: