Step 3: Assemble provided PV connectors with PV modules by the following below
steps.
Components for PV connectors and Tools:
Female connector housing
Female terminal
Male connector housing
Male terminal
Crimping tool and spanner
Cable preparation and connector assembly process:
Strip one cable 8 mm on both end sides and be
careful NOT to nick conductors.
Insert striped cable into female terminal and
crimp female terminal as shown below charts.
Insert assembled cable into female connector housing as shown below charts.
Insert striped cable into male terminal and crimp male terminal as shown below charts.
Insert assembled cable into male connector housing as shown below charts.
Then, use spanner to screw pressure dome tightly to female connector and male
connector as shown below.
Step 2: Disconnect the circuit breaker and switch off the DC switch.
Step 4: Check correct polarity of connection cable from PV modules and PV input
connectors. Then, connect positive pole (+) of connection cable to positive pole (+)
of PV input connector. Connect negative pole (-) of connection cable to negative pole
(-) of PV input connector.
WARNING!
appropriate cable for PV module connection. To reduce risk of injury, please use the
proper recommended cable size as below.
It's very important for system safety and efficient operation to use
Figure 6.2
Figure 6.3
Figure 6.4
Figure 6.5
Figure 6.6
Figure 6.7
Table 6.1
15