6.3.5 Data checking and parameters setting
Cycle display
If you do not knock the enclosure lid, LCD display following information cycle by
cycle. Refer Fig 6.3.3.
Fig 6.3.3 Cycle display
Parameters setting
AC VA/Watt:
VA W
Etoday:
50 .2 Kwh
Eall:
2000 Kwh
Fig 6.3.4 is the setting information. Single knock, the Text will display the setting.
Double knock, the Text will display”input123: 000”. Single knock to go back Setting
page. Double knock the enclosure lid ready to input password. Single knock to
change value of first, double knock enter into next position. Konck three times when
the bit was “123”, it will go into Setting options.
Input Word:123
000
Input Word:123
0
00
Double
Input Word:123
1
0
0
Input Word:123
1
00
Input Word:123
1
1
0
Once
Once
Double
Input Word:123
1
2
0
O
n
ce
Input Word:123
12
0
Double
Input Word:123
12
1
Once
Input Word:123
12
2
Once
Input Word:123
12
3
Once
Setting
Double
Three
Input OK
33
34
Fig 6.3.4 setting second level menu and its sub-menus
Set Com Address
001
Set Language
Set Date/Time
AC V Control :
Disable/Enable
Once
Once
Once
Setting
Three
Set Language
English
Double
AC V Control :
Disable
Double
Double
Date
:
20
12/04/05
Time
:
14:20:38
Setting language
To change inverter’s displaying language, please select Setting->Set language, then
LCD screen will display current language type, single knock to change current
language, knock three times will save changes and displays “Set OK! Current
Language English” Refer Fig 6.3.5. Knock four times to exit setting.
Set Language
Set Language
English
Set Language
xxxx
Once
Three
Set OK
Fig 6.3.5 setting language
Please note in order to prevent disoperation, system language won’t be change in
second level menu “Set language”, but it will be only if user saves save the choice by
knock three times and LCD displays “Set OK!”
Setting inverter’s COM address
When communicating with monitoring software or device, the software or device
may regard inverter’s COM address as communication address (Also may use
inverter’s serial number as communication address).The COM address could be
assigned. The second level menu “Set COM Addr” of setting is to set inverter’s COM
address.