27
28
2635.1W 10.3Var
Input 123: xxx
2849.1W 18.3Var
Language: English
2769.1W 28.3Var
Set Language
2869.8W 21.3Var
COM Address: xxx
3269.8W 25.3Var
Net model: x
3321.8W 16.3Var
Zegbee: xxxxxxxx
Set input page
Language
Set language
Set commucation address
4
4
4
4
4
4
Set Net Model
Zigbee status
7.2 Setting the LCD display
7.2.1 Knock type and definition
The inverter can support three kinds of knock: single knock, double knock and thrice
knock. Each kind of knock has different function. Refer to specified definition in Table
below
:
Knock type
Single knock
Double knock
Thrice knock
Definition
KeyDown
KeySET
KeyEnter&ESC
Befor light the background, the types of knock functions are the same: just light the
background.
NOTE: That the background light will automatically off if there is no knock detected in
ten seconds.
Sound control can define the display language, communication address and utility
model choice.
7.2.2 Read AC Error record information
When the LCD is dark, a knock and double knock will activate LCD. Knock to change
the situation, enter to 'AC Error record' page. Double knock to information read state,
Display show as follows:
2324.5W 16. 7Var
AC Error Record
1: NO AC
2018/10/15 08:21
2: AC F out range
2018/12/05 11: 21
5: AC V out range
2018/10/ 15 08:21
4: NO AC
2018/11/08 12:21
3: NO AC
2018/11/05 17: 31
Single knock
Single knock
Single knock
Single knock
Sin
gle k
noc
k
Double knock
7.2.3 Enter to SET
When the LCD is dark, a knock and double knock will activate LCD. Knock to display
next information or change the set situation. Double knock makes the display stand
for 30 seconds, enter to setting state. Display show as follows:
2324.5W 16.7 Var
Input 123: 000
2324.5W 16.7Var
Input 123:
0
00
2324.5W 16. 7Var
Input 123: 1
2
0
2324.5W 16.7 Var
Input 123: 1
0
0
2324.5W 16.7Var
Input 123:
1
00
2324.5W 16. 7Var
Input 123: 12
0
2324.5W 16.7 Var
Input 123: 12
3
2324.5W 16.7Var
Set Language
Single knock
Double knock
Double knock
2324.5W 16. 7Var
Setting
Double knock
Single knock
Double knock
Single knock
Thrice knock
Enter to
setting state
7.2.4 Setting inverter display language
On the set situation page knock to 'Set language' double knock to enter 'language:
English' knock to select the language you need and thrice knock to enter or wait until
the display become dark.
7.2.5 Setting communication address
On the set situation page knock to 'COM Address: xx' double knock to change the
Address model knock to set address, thrice knock to enter or wait until the display