background image

27

28

 

2635.1W     10.3Var      
Input  123:         xxx

 

2849.1W     18.3Var      
Language:    English

 

2769.1W     28.3Var       
Set    Language

 

2869.8W     21.3Var       
COM  Address:  xxx

 

3269.8W     25.3Var       
Net  model:    x

 

3321.8W     16.3Var       
Zegbee:     xxxxxxxx

Set input page

Language

Set language

Set commucation address

4

4

4

4

4

4

Set Net Model

Zigbee status

7.2 Setting the LCD display

7.2.1 Knock type and definition

The inverter can support three kinds of knock: single knock, double knock and thrice 
knock. Each kind of knock has different function. Refer to specified definition in Table 
below

Knock type

Single knock

Double knock

Thrice knock

Definition

KeyDown

KeySET

KeyEnter&ESC

Befor light the background, the types of knock functions are the same: just light the 
background.
NOTE: That the background light will automatically off if there is no knock detected in 
ten seconds.
Sound control can define the display language, communication address and utility 
model choice.

7.2.2 Read AC Error record information

When the LCD is dark, a knock and double knock will activate LCD. Knock to change 
the situation, enter to 'AC Error record' page. Double knock to information read state, 
Display show as follows:

 

2324.5W     16. 7Var      
AC Error Record

1:   NO AC          
2018/10/15    08:21

2:  AC F out range        
2018/12/05    11: 21

5:  AC V out range          
2018/10/ 15    08:21

4:   NO AC          
2018/11/08    12:21

3:   NO AC          
2018/11/05    17: 31

Single knock

Single knock

Single knock

Single knock

Sin

gle k

noc

k

Double knock

7.2.3 Enter to SET

When the LCD is dark, a knock and double knock will activate LCD. Knock to display 
next information or change the set situation. Double knock makes the display stand 
for 30 seconds, enter to setting state. Display show as follows:

 

2324.5W     16.7 Var      
Input    123:        000

2324.5W     16.7Var      
Input    123:      

0

00

2324.5W     16. 7Var      
Input    123:       1

2

0

2324.5W     16.7 Var      
Input    123:       1

0

0

2324.5W     16.7Var      
Input    123:      

1

00

2324.5W     16. 7Var      
Input    123:       12

0

2324.5W     16.7 Var      
Input    123:       12

3

2324.5W     16.7Var      
Set   Language

Single knock

Double knock

Double knock

2324.5W     16. 7Var      
Setting

Double knock

Single knock

Double knock

Single knock

Thrice knock

Enter to 

setting state

7.2.4 Setting inverter display language 

On the set situation page    knock to 'Set language'    double knock to enter 'language: 
English'    knock to select the language you need and thrice knock to enter or wait until 
the display become dark.

7.2.5  Setting communication address

On the set situation page    knock to 'COM Address: xx'    double knock to change the 
Address model    knock to set address, thrice knock to enter or wait until the display 
become dark.

Summary of Contents for 10500MTLP-S

Page 1: ...ict Shenzhen P R China No 28 Guangming Road Shiyan Street Bao an District Shenzhen P R China GR UM 157 A 00 86 0755 2747 1942 86 0755 2747 1942 www ginverter com www ginverter com T E W service ginver...

Page 2: ...ion of skilled person 2 3 Safety instruction 2 4 Assembly Warnings 2 5 Electrical Connection Warnings 2 6 Operation Warnings 1 1 Validity 1 2 Target Group 1 3 Additional information 1 4 Symbols in thi...

Page 3: ...tion 13 2 DC connector info 13 3 Torque 13 4 Accessories 6 Electrical connection 12 Decommissioning 7 Commissioning 13 Technical Data 14 PV system installation 7 1 LCD display 7 2 Setting the LCD disp...

Page 4: ...the Growatt equipment or personal injury This manual describes the assembly installation commissioning and maintenance of the following Growatt Inverter model Growatt 8000MTLP S Growatt 9000MTLP S Gr...

Page 5: ...d safety rules Nevertheless improper use may cause lethal hazards for the operator or third parties or may result in damage to the units and other property Principle of a PV plant with thisGROWATT XXX...

Page 6: ...ay from children There is residual voltage in the inverter The inverter takes 20 minutes to ischarge The components in the inverter are live Touching live components can result in serious injury or de...

Page 7: ...standardized emission limit values e g when sensitive equipment is located at the setup location or when the setup location is near radio or television receivers In this case the operator is obliged t...

Page 8: ...age local installer or service department of GROWATT should perform a comprehensive test before installation Maximum efficiency of 98 1 Wide input voltage range from 100 600Vdc Reactive power regulate...

Page 9: ...nal PV PV metal terminal RS485 Waterproof cover AC Waterproof cover All electrical installations shall be done in accordance with the local and national electrical codes Do not remove the casing Inver...

Page 10: ...condensation The installation location must be freely and safely to get at all times Vertically installation and make sure the connection of inverter must be downwards Never install horizontal and avo...

Page 11: ...nstalled at the right place The inverter can t install close to trunk Information General tools 1 Personal safety equipment such as gloves helmet goggles ear plugs safety harness etc 2 Step ladders 3...

Page 12: ...he inverter on the bracket unless you are sure that the mounting frame is really firmly mounted on the wall after carefully checking WARNING WARNING WARNING Using the mounting frame as a template dril...

Page 13: ...esidual current you must choose a AC breaker with the rating residual current more than 300mA We suggest you choice the AC breaker rating current in this table we recommend electrical connection as fo...

Page 14: ...ut don t have to screw it completely as shown below 2 Plugging the connected wire RS485 terminal into the RS485 terminal of the inverter as shown below 3 Lock the RS waterproof cover to the inverter c...

Page 15: ...phase inverter has three independent MPPT A B and C the MPPT A has two independent PV array inputs MPPT B and MPPT C have one PV array input the corresponding terminal block is shown below 2 The PV c...

Page 16: ...er can be controlled by knocking on the front of it The first line will show some status of the inverter there are 4 status listed in below table Inverter State Fault State Program State DISPLAY CONTE...

Page 17: ...ws 2324 5W 16 7Var AC Error Record 1 NO AC 2018 10 15 08 21 2 AC F out range 2018 12 05 11 21 5 AC V out range 2018 10 15 08 21 4 NO AC 2018 11 08 12 21 3 NO AC 2018 11 05 17 31 Single knock Single kn...

Page 18: ...to the inverter data by accessing the sever More details can be found in the Wifi module manual 1 Connect the AC breaker of the inverter 2 Turn on the dc switch and the inverter will start automatical...

Page 19: ...ity grid voltage or frequency change frequently 10 2 Warnings W Warnings W identify the current status of the Growatt 8 10K MTLP S inverter Warnings do not relate to a fault When a W with a number aft...

Page 20: ...er with household waste Please accordance with the disposal regulations for electronic waste which apply at the installation site at that time Ensure that the old unit and where applicable any accesso...

Page 21: ...Certificatesand approvals INMETRO IEC61727 62116 Interfaces RS485 RF WiFi GPRS yes opt opt opt 13 2 DC connector info 13 3 Torque DC connector Enclosure lid screws Shell and RS232 screws AC terminal...

Page 22: ...he appropriate settings the unit will comply with the requirements specified in the following standards and directives dated December 2018 INMETRO IEC61727 62116 GROWATT can preset special grid parame...

Page 23: ...cessary assistance Inverter type Serial number of the inverter Event number or display message of the inverter Type and number of PV modules connected Optional equipment GROWATT NEW ENERGY TECHNOLOGY...

Reviews: