Notes on this manual

1.1 Validity

1

2

1.2 Target Group

This manual is for qualified personnel. Qualified personnel have received training and 
have  demonstrated  skills  and  knowledge  in  the  construction  and  operation  of  this 
device. Qualified Personnel are trained to deal with the dangers and hazards involved 
in installing electric devices.

1.3 Additional information

Find further information on special topics in the download area at www.ginverter.com
The manual and other documents must be stored in a convenient place and be 
available at all times. We assume no liability for any damage caused by failure to 
observe these instructions. For possible changes in this manual, GROWATT NEW 
ENERGY TECHNOLOGY CO.,LTD accepts no responsibilities to inform the users.

1.4.2 Markings on this product

1.4 Symbols in this document

1.4.1 Symbols in this document

A  warning  describes  a  hazard  to  equipment  or  personnel.  It  calls  attention  to  a 
procedure or practice, which, if not correctly performed or adhered to, could result in 
damage  to  or  destruction  of  part  or  all  of  the  Growatt  equipment  and/or  other 
equipment connected to the Growatt equipment or personal injury.

This manual describes the assembly, installation, commissioning and maintenance of 
the following Growatt Inverter model:
Growatt 8000MTLP-S
Growatt 9000MTLP-S
Growatt 10500MTLP-S

This  manual  does  not  cover  any  details  concerning  equipment  connected  to  the 
MTLP-S(  e.g.  PV  modules).  Information  concerning  the  connected  equipment  is 
available from -the manufacturer of the equipment.

CAUTION

CAUTION  indicates  a  hazardous  situation  which,  if  not  avoided, 
could result in minor or moderate injury.

NOTICE  is  used  to  address  practices  not  related  to  personal 
injury.

Information that you must read and know to ensure optimal 
operation of the system.

NOTICE

Information

WARNING

DANGER

Symbol

description

DANGER  indicates  a  hazardous  situation  which,  if  not  avoided, 
will result in death or serious injury.

WARNING  indicates  a  hazardous  situation  which,  if  not  avoided, 
could result in death or serious injury.

Symbol

Explanation

Electrical voltage!

Point of connection for grounding protection

Risk of burns

Alternating Current (AC)

Risk of fire or explosion

Direct Current (DC) 

Operation after 5 minutes

Read the manual

CE mark.
The  inverter  complies  with  the  requirements  of  the  applicable 
CE guidelines.

The  inverter  must  not  be  disposed  of  with  the  household 
waste.

The inverter has no transformer.

Summary of Contents for 10500MTLP-S

Page 1: ...ict Shenzhen P R China No 28 Guangming Road Shiyan Street Bao an District Shenzhen P R China GR UM 157 A 00 86 0755 2747 1942 86 0755 2747 1942 www ginverter com www ginverter com T E W service ginver...

Page 2: ...ion of skilled person 2 3 Safety instruction 2 4 Assembly Warnings 2 5 Electrical Connection Warnings 2 6 Operation Warnings 1 1 Validity 1 2 Target Group 1 3 Additional information 1 4 Symbols in thi...

Page 3: ...tion 13 2 DC connector info 13 3 Torque 13 4 Accessories 6 Electrical connection 12 Decommissioning 7 Commissioning 13 Technical Data 14 PV system installation 7 1 LCD display 7 2 Setting the LCD disp...

Page 4: ...the Growatt equipment or personal injury This manual describes the assembly installation commissioning and maintenance of the following Growatt Inverter model Growatt 8000MTLP S Growatt 9000MTLP S Gr...

Page 5: ...d safety rules Nevertheless improper use may cause lethal hazards for the operator or third parties or may result in damage to the units and other property Principle of a PV plant with thisGROWATT XXX...

Page 6: ...ay from children There is residual voltage in the inverter The inverter takes 20 minutes to ischarge The components in the inverter are live Touching live components can result in serious injury or de...

Page 7: ...standardized emission limit values e g when sensitive equipment is located at the setup location or when the setup location is near radio or television receivers In this case the operator is obliged t...

Page 8: ...age local installer or service department of GROWATT should perform a comprehensive test before installation Maximum efficiency of 98 1 Wide input voltage range from 100 600Vdc Reactive power regulate...

Page 9: ...nal PV PV metal terminal RS485 Waterproof cover AC Waterproof cover All electrical installations shall be done in accordance with the local and national electrical codes Do not remove the casing Inver...

Page 10: ...condensation The installation location must be freely and safely to get at all times Vertically installation and make sure the connection of inverter must be downwards Never install horizontal and avo...

Page 11: ...nstalled at the right place The inverter can t install close to trunk Information General tools 1 Personal safety equipment such as gloves helmet goggles ear plugs safety harness etc 2 Step ladders 3...

Page 12: ...he inverter on the bracket unless you are sure that the mounting frame is really firmly mounted on the wall after carefully checking WARNING WARNING WARNING Using the mounting frame as a template dril...

Page 13: ...esidual current you must choose a AC breaker with the rating residual current more than 300mA We suggest you choice the AC breaker rating current in this table we recommend electrical connection as fo...

Page 14: ...ut don t have to screw it completely as shown below 2 Plugging the connected wire RS485 terminal into the RS485 terminal of the inverter as shown below 3 Lock the RS waterproof cover to the inverter c...

Page 15: ...phase inverter has three independent MPPT A B and C the MPPT A has two independent PV array inputs MPPT B and MPPT C have one PV array input the corresponding terminal block is shown below 2 The PV c...

Page 16: ...er can be controlled by knocking on the front of it The first line will show some status of the inverter there are 4 status listed in below table Inverter State Fault State Program State DISPLAY CONTE...

Page 17: ...ws 2324 5W 16 7Var AC Error Record 1 NO AC 2018 10 15 08 21 2 AC F out range 2018 12 05 11 21 5 AC V out range 2018 10 15 08 21 4 NO AC 2018 11 08 12 21 3 NO AC 2018 11 05 17 31 Single knock Single kn...

Page 18: ...to the inverter data by accessing the sever More details can be found in the Wifi module manual 1 Connect the AC breaker of the inverter 2 Turn on the dc switch and the inverter will start automatical...

Page 19: ...ity grid voltage or frequency change frequently 10 2 Warnings W Warnings W identify the current status of the Growatt 8 10K MTLP S inverter Warnings do not relate to a fault When a W with a number aft...

Page 20: ...er with household waste Please accordance with the disposal regulations for electronic waste which apply at the installation site at that time Ensure that the old unit and where applicable any accesso...

Page 21: ...Certificatesand approvals INMETRO IEC61727 62116 Interfaces RS485 RF WiFi GPRS yes opt opt opt 13 2 DC connector info 13 3 Torque DC connector Enclosure lid screws Shell and RS232 screws AC terminal...

Page 22: ...he appropriate settings the unit will comply with the requirements specified in the following standards and directives dated December 2018 INMETRO IEC61727 62116 GROWATT can preset special grid parame...

Page 23: ...cessary assistance Inverter type Serial number of the inverter Event number or display message of the inverter Type and number of PV modules connected Optional equipment GROWATT NEW ENERGY TECHNOLOGY...

Reviews: