background image

5

6

2.5 Electrical Connection Warnings

Ø

Prior to installation, inspect the unit to ensure absence of any 

transport or handling damage, which could affect insulation 
integrity or safety clearances; failure to do so could result in 
safety hazards.

Ø

Assemble the inverter per the instructions in this manual. Use 

care when choosing installation location and adhere to specified 
cooling requirements.

Ø

Unauthorized removal of necessary protections, improper use, 

incorrect installation and operation may lead to serious safety 
and shock hazards and/or equipment damage.

Ø

In order to minimize the potential of a shock hazard due to 

hazardous voltages, cover the entire solar array with dark 
material prior to connecting the array to any equipment.

Ø

Grounding  the  PV  modules

The  Growatt

MTLP-S  is  a 

transformerless  inverter.  That  is  why  it  has  no  galvanic 
separation.  Do  not  ground  the  DC  circuits  of  the  PV  modules 
connected  to  the  Growatt

MTLP-S.  Only  ground  the  mounting 

frame  of  the  PV  modules.If  you  connect  grounded  PV  modules 
to the Growatt

MTLP-S, the error message "PV ISO Low".

Ø

Comply  with  the  local  requirements  for  grounding  the  PV               

modules  and  the  PV  generator.  GROWATT  recommends 
c o n n e c t i n g  t h e  g e n e r a t o r  f r a m e  a n d  o t h e r  e l e c t r i c a l l y 
conductive  surfaces  in  a  manner  which  ensures  continuous 
conduction with ground in order to have optimal protection of the 
system and personnel.

WARNING

CAUTION

Ÿ

Do not open the inverter except the wire box by qualified persons.

Ÿ

Electrical installation, repairs and conversions may only be 
carried out by electrically qualified persons.

Ÿ

Do not touch damaged inverters.

Ø

Danger to life due to high voltages in the inverter

Ø

Persons with limited physical or mental abilities may only work 

with the Growatt inverter following proper instruction and under 
constant supervision. Children are forbidden to play with the 
Growatt inverter. Must keep the Growatt inverter away from 
children.

Ÿ

There is residual voltage in the inverter. The inverter takes 20 

minutes to ischarge.

Ø

The components in the inverter are live. Touching live 

components can result in serious injury or death.

DANGER

2

.

4

 

Assembly Warnings

CAUTION

Ø

Make all electrical connections (e.g. conductor termination, 

fuses, PE connection, etc.) in accordance with prevailing 
regulations. When working with the inverter powered on, 
adhere to all prevailing safety regulations to minimize risk of 
accidents.

Ø

Systems  with  inverters  typically  require  additional  control 

(e.g., switches, disconnects) or protective devices (e.g., fusing 
circuit breakers) depending upon the prevailing safety rules.

WARNING

Ø

The Growatt Inverter converts DC Current from PV generator 
into AC current. The inverter is suitable for mounting indoors 
and outdoors.

Ø

You can use the AC current gernerated as follows:

House grid:

Public grid:

Energy flows into the house grid. The consumers 
connected, for example, household devices or 
lighting, consume the energy. The energy left over 
is fed into the public grid. When the Growatt is not 
gernerating any energy, e.g., at night, the 
consumers which are connected are supplied by 
the public grid.The Growatt does not have its own 
energy meter. When energy is fed into the public 
grid, the energy meter spins backwards.

Energy is fed directly into the public grid. The 
Growatt is connected to a separate energy meter. 
The energy produced is compensated at a rate 
depending on the electric power company.

2.6 Operation Warnings

WARNING

Ø

Ensure all connectors are sealed and secure during operation.

Ø

Although designed to meet all safety requirements, some parts 

and  surfaces  of  Inverter  are  still  hot  during  operation.  To 
reduce the risk of injury, do not touch the heat sink at the back 
of  the  PV-Inverter  or  nearby  surfaces  while  Inverter  is 
operating.

Ø

Incorrect  sizing  of  the  PV  plant  may  result  in  voltages  being 

present  which  could  destroy  the  inverter.  The  inverter  display 
will read the error message “PV voltage High!”

Ÿ

Turn  the  rotary  switch  of  the  DC  Disconnect  to  the  Off  position 

immediately.

Ÿ

Contact installer.

Summary of Contents for 10500MTLP-S

Page 1: ...ict Shenzhen P R China No 28 Guangming Road Shiyan Street Bao an District Shenzhen P R China GR UM 157 A 00 86 0755 2747 1942 86 0755 2747 1942 www ginverter com www ginverter com T E W service ginver...

Page 2: ...ion of skilled person 2 3 Safety instruction 2 4 Assembly Warnings 2 5 Electrical Connection Warnings 2 6 Operation Warnings 1 1 Validity 1 2 Target Group 1 3 Additional information 1 4 Symbols in thi...

Page 3: ...tion 13 2 DC connector info 13 3 Torque 13 4 Accessories 6 Electrical connection 12 Decommissioning 7 Commissioning 13 Technical Data 14 PV system installation 7 1 LCD display 7 2 Setting the LCD disp...

Page 4: ...the Growatt equipment or personal injury This manual describes the assembly installation commissioning and maintenance of the following Growatt Inverter model Growatt 8000MTLP S Growatt 9000MTLP S Gr...

Page 5: ...d safety rules Nevertheless improper use may cause lethal hazards for the operator or third parties or may result in damage to the units and other property Principle of a PV plant with thisGROWATT XXX...

Page 6: ...ay from children There is residual voltage in the inverter The inverter takes 20 minutes to ischarge The components in the inverter are live Touching live components can result in serious injury or de...

Page 7: ...standardized emission limit values e g when sensitive equipment is located at the setup location or when the setup location is near radio or television receivers In this case the operator is obliged t...

Page 8: ...age local installer or service department of GROWATT should perform a comprehensive test before installation Maximum efficiency of 98 1 Wide input voltage range from 100 600Vdc Reactive power regulate...

Page 9: ...nal PV PV metal terminal RS485 Waterproof cover AC Waterproof cover All electrical installations shall be done in accordance with the local and national electrical codes Do not remove the casing Inver...

Page 10: ...condensation The installation location must be freely and safely to get at all times Vertically installation and make sure the connection of inverter must be downwards Never install horizontal and avo...

Page 11: ...nstalled at the right place The inverter can t install close to trunk Information General tools 1 Personal safety equipment such as gloves helmet goggles ear plugs safety harness etc 2 Step ladders 3...

Page 12: ...he inverter on the bracket unless you are sure that the mounting frame is really firmly mounted on the wall after carefully checking WARNING WARNING WARNING Using the mounting frame as a template dril...

Page 13: ...esidual current you must choose a AC breaker with the rating residual current more than 300mA We suggest you choice the AC breaker rating current in this table we recommend electrical connection as fo...

Page 14: ...ut don t have to screw it completely as shown below 2 Plugging the connected wire RS485 terminal into the RS485 terminal of the inverter as shown below 3 Lock the RS waterproof cover to the inverter c...

Page 15: ...phase inverter has three independent MPPT A B and C the MPPT A has two independent PV array inputs MPPT B and MPPT C have one PV array input the corresponding terminal block is shown below 2 The PV c...

Page 16: ...er can be controlled by knocking on the front of it The first line will show some status of the inverter there are 4 status listed in below table Inverter State Fault State Program State DISPLAY CONTE...

Page 17: ...ws 2324 5W 16 7Var AC Error Record 1 NO AC 2018 10 15 08 21 2 AC F out range 2018 12 05 11 21 5 AC V out range 2018 10 15 08 21 4 NO AC 2018 11 08 12 21 3 NO AC 2018 11 05 17 31 Single knock Single kn...

Page 18: ...to the inverter data by accessing the sever More details can be found in the Wifi module manual 1 Connect the AC breaker of the inverter 2 Turn on the dc switch and the inverter will start automatical...

Page 19: ...ity grid voltage or frequency change frequently 10 2 Warnings W Warnings W identify the current status of the Growatt 8 10K MTLP S inverter Warnings do not relate to a fault When a W with a number aft...

Page 20: ...er with household waste Please accordance with the disposal regulations for electronic waste which apply at the installation site at that time Ensure that the old unit and where applicable any accesso...

Page 21: ...Certificatesand approvals INMETRO IEC61727 62116 Interfaces RS485 RF WiFi GPRS yes opt opt opt 13 2 DC connector info 13 3 Torque DC connector Enclosure lid screws Shell and RS232 screws AC terminal...

Page 22: ...he appropriate settings the unit will comply with the requirements specified in the following standards and directives dated December 2018 INMETRO IEC61727 62116 GROWATT can preset special grid parame...

Page 23: ...cessary assistance Inverter type Serial number of the inverter Event number or display message of the inverter Type and number of PV modules connected Optional equipment GROWATT NEW ENERGY TECHNOLOGY...

Reviews: