background image

12

11

5.1 Safety instructions

4

 

Unpacking and inspection

Installation 5

 

Danger to life due to fire or explosion

Ø

Despite careful construction, electrical devices can cause 
fires.

Ø

Do  not  install  the  inverter  on  easily  flammable  materials  and 

where flammable materials are stored.

Risk of burns due to hot enclosure parts

Mount  the  inverter  in  such  a  way  that  it  cannot  be  touched 
inadvertently.

The inverter is thoroughly tested and inspected strictly before delivery. Our inverters 
leave our factory in proper electrical and mechanical condition. Special packaging 
ensures safe and careful transportation. However, transport damage may still occur. 
The shipping company is responsible in such cases. Thoroughly inspect the inverter 
upon delivery. Immediately notify the responsible shipping company if you discover 
any damage to the packaging which indicates that the inverter may have been 
damaged or if you discover any visible damage to the inverter. We will be glad to assist 
you, if required. When transporting the inverter, the original or equivalent packaging 
should be used, and the maximum layers for original carton is four, as this ensures 
safe transport.

After opening the package, please check the contents of the box. It should contain the 
following, Please check all of the accessories carefully in the carton. If anything 
missing, contact your dealer at once.

Quantity

A

B

C

D

E

F

G

H

I

J

K

L

Inverter

Quick Guide

1

1

1

1

2

4

4

4/4

4/4

6

1

1

Object

Description

User manual

Cross Combination Screw

RS485 Connectors

Explosion bolt 

OT Terminal

Countersunk head screw

PV+/PV- terminal

PV+/PV- metal terminal

RS485 Waterproof cover

AC Waterproof cover

Ø

All electrical installations shall be done in accordance with the local and national 

electrical codes. Do not remove the casing. Inverter contains no user serviceable 
parts. Refer servicing to qualified service personnel. all wiring and electrical 
installation should be conducted by a qualified service personnel .

Ø

Carefully remove the unit from its packaging and inspect for external damage. If 

you find any imperfections, please contact your local dealer.

Ø

Be sure that the inverters connect to the ground in order to protect property and 
personal safety.

Ø

The inverter must only be operated with PV generator. Do not connect any other 

source of energy to it.

Ø

Both AC and DC voltage sources are terminated inside the PV Inverter. Please 

disconnect these circuits before servicing.

Ø

This unit is designed to feed power to the public power grid (utility) only. Do not 

connect this unit to an AC source or generator. Connecting Inverter to external 
devices could result in serious damage to your equipment.

Ø

When a photovoltaic panel is exposed to light, it generates a DC voltage. When 
connected to this equipment, a photovoltaic panel will charge the DC link 
capacitors. 

Ø

Energy stored in this equipment's DC link capacitors presents a risk of electric 

shock. Even after the unit is disconnected from the grid and photovoltaic panels, 
high voltages may still exist inside the PV-Inverter. Do not remove the casing 
until at least  5  minutes after disconnecting all power sources.

Ø

Although designed to meet all safety requirements, some parts and surfaces of 

Inverter are still hot during operation. To reduce the risk of injury, do not touch the 
heat sink at the back of the PV-Inverter or nearby surfaces while Inverter is 
operating. 

Summary of Contents for 10500MTLP-S

Page 1: ...ict Shenzhen P R China No 28 Guangming Road Shiyan Street Bao an District Shenzhen P R China GR UM 157 A 00 86 0755 2747 1942 86 0755 2747 1942 www ginverter com www ginverter com T E W service ginver...

Page 2: ...ion of skilled person 2 3 Safety instruction 2 4 Assembly Warnings 2 5 Electrical Connection Warnings 2 6 Operation Warnings 1 1 Validity 1 2 Target Group 1 3 Additional information 1 4 Symbols in thi...

Page 3: ...tion 13 2 DC connector info 13 3 Torque 13 4 Accessories 6 Electrical connection 12 Decommissioning 7 Commissioning 13 Technical Data 14 PV system installation 7 1 LCD display 7 2 Setting the LCD disp...

Page 4: ...the Growatt equipment or personal injury This manual describes the assembly installation commissioning and maintenance of the following Growatt Inverter model Growatt 8000MTLP S Growatt 9000MTLP S Gr...

Page 5: ...d safety rules Nevertheless improper use may cause lethal hazards for the operator or third parties or may result in damage to the units and other property Principle of a PV plant with thisGROWATT XXX...

Page 6: ...ay from children There is residual voltage in the inverter The inverter takes 20 minutes to ischarge The components in the inverter are live Touching live components can result in serious injury or de...

Page 7: ...standardized emission limit values e g when sensitive equipment is located at the setup location or when the setup location is near radio or television receivers In this case the operator is obliged t...

Page 8: ...age local installer or service department of GROWATT should perform a comprehensive test before installation Maximum efficiency of 98 1 Wide input voltage range from 100 600Vdc Reactive power regulate...

Page 9: ...nal PV PV metal terminal RS485 Waterproof cover AC Waterproof cover All electrical installations shall be done in accordance with the local and national electrical codes Do not remove the casing Inver...

Page 10: ...condensation The installation location must be freely and safely to get at all times Vertically installation and make sure the connection of inverter must be downwards Never install horizontal and avo...

Page 11: ...nstalled at the right place The inverter can t install close to trunk Information General tools 1 Personal safety equipment such as gloves helmet goggles ear plugs safety harness etc 2 Step ladders 3...

Page 12: ...he inverter on the bracket unless you are sure that the mounting frame is really firmly mounted on the wall after carefully checking WARNING WARNING WARNING Using the mounting frame as a template dril...

Page 13: ...esidual current you must choose a AC breaker with the rating residual current more than 300mA We suggest you choice the AC breaker rating current in this table we recommend electrical connection as fo...

Page 14: ...ut don t have to screw it completely as shown below 2 Plugging the connected wire RS485 terminal into the RS485 terminal of the inverter as shown below 3 Lock the RS waterproof cover to the inverter c...

Page 15: ...phase inverter has three independent MPPT A B and C the MPPT A has two independent PV array inputs MPPT B and MPPT C have one PV array input the corresponding terminal block is shown below 2 The PV c...

Page 16: ...er can be controlled by knocking on the front of it The first line will show some status of the inverter there are 4 status listed in below table Inverter State Fault State Program State DISPLAY CONTE...

Page 17: ...ws 2324 5W 16 7Var AC Error Record 1 NO AC 2018 10 15 08 21 2 AC F out range 2018 12 05 11 21 5 AC V out range 2018 10 15 08 21 4 NO AC 2018 11 08 12 21 3 NO AC 2018 11 05 17 31 Single knock Single kn...

Page 18: ...to the inverter data by accessing the sever More details can be found in the Wifi module manual 1 Connect the AC breaker of the inverter 2 Turn on the dc switch and the inverter will start automatical...

Page 19: ...ity grid voltage or frequency change frequently 10 2 Warnings W Warnings W identify the current status of the Growatt 8 10K MTLP S inverter Warnings do not relate to a fault When a W with a number aft...

Page 20: ...er with household waste Please accordance with the disposal regulations for electronic waste which apply at the installation site at that time Ensure that the old unit and where applicable any accesso...

Page 21: ...Certificatesand approvals INMETRO IEC61727 62116 Interfaces RS485 RF WiFi GPRS yes opt opt opt 13 2 DC connector info 13 3 Torque DC connector Enclosure lid screws Shell and RS232 screws AC terminal...

Page 22: ...he appropriate settings the unit will comply with the requirements specified in the following standards and directives dated December 2018 INMETRO IEC61727 62116 GROWATT can preset special grid parame...

Page 23: ...cessary assistance Inverter type Serial number of the inverter Event number or display message of the inverter Type and number of PV modules connected Optional equipment GROWATT NEW ENERGY TECHNOLOGY...