5.2 Selecting the installation location
This is guidance for installer to choose a suitable installation location, to avoid
potential damages to device and operators.
Raintight or wet location hubs that comply with the requirements in the
Standard for Conduit, Tubing, and Cable Fittings, UL 514B, are to be used.
The unit shall be mounted at least 914 mm (3 feet) above the ground.
The installation location must be suitable for the inverter's weight and
dimensions for a long period time.
Select the installation location so that the status display can be easily viewed.
Do not install the inverter on structures constructed of flammable or
thermolabile materials.
The humidity of the installation location should be 0~95% without
condensation.
The installation location must be freely and safely to get at all times.
Vertically installation or tilted backwards by max. 15°. and make sure the
connection of inverter must be downwards. Never install horizontal and avoids
forward and sideways tilt.
Be sure that the inverter is out of the children's reach.
Don't put any things on the inverter. Do not cover the inverter.
Do not install the inverter near television antenna or any other antennas,
antenna cables.
Inverter requires adequate cooling space. Providing better ventilation for the
inverter to ensure the heat escape adequately. The ambient temperature should be
below 40°C to ensure optimum operation. Please make sure the inverter is installed
at the right place
The inverter can't install close to trunk
,
。
The inverter can't install to direct sunlight drench,firn location. We suggest that
the inverters should be installed at the location with some cover or protection
,
.
Observe the minimum clearances to walls, other inverters or objects as shown in
the diagram below in order to guarantee sufficient heat dissipation.
Direction
Min.clearance(cm)
above
30
below
sides
front
50
30
30