5. Make the heat shrink tubes wrap the joint.
5. Make the heat shrink tubes wrap the joint.
7. Connect the RS485 connector onto the inverter. Make sure the
connection matched ('1' to '1', '2' to '2').
7.4 Using shine tool to set the information of the inverter
About the software of shine tool and the usage of it please
download from the web:
www.ginverter.com/Download.aspx
Start-Up and shut down the inverter
8
Start-Up and shut down the inverter
8
8.1 Start-Up the inverter
1. Connect the AC circuit breaker
2. Turn on the DC switch, and the inverter will start automatically when the input
voltage is higher than 150V.
8.2 Disconnecting the Inverter
1. Disconnect the AC circuit breaker and prevent it from being reactivated.
2. Turn off the dc switch.
3. Check the inverter operating status.
4. Waiting until LED,LCD display have gone out, the inverter is shut down.
Maintenance and Cleaning
9
Maintenance and Cleaning
9
9.1 Checking Heat Dissipation
If the inverter regularly reduces its output power due to high temperature, please
improve the heat dissipation condition. Maybe you need to clean the heat sink.
9.2 Cleaning the Inverter
If the inverter is dirty, shut down the inverter, then clean the enclosure lid, the
display, and the LEDs using only a wet cloth. Do not use any cleaning agents (e.g.
solvents or abrasives).
37