background image

The warranties described in these “Limited Warranties” are exclusive and are

expressly in lieu of and exclude all other warranties, whether written, oral, express or

implied, including but not limited to, warranties of merchantability and of fitness for

a particular purpose, use

or application, and all other obligations or liabilities on

the part of Growatt

unless such other obligations or liabilities are expressly agreed

to it in writing signed and approved by Growatt

Growatt shall have no

responsibility or liability whatsoever for damage or injury to persons or property, or

for other loss or injury resulting from any cause whatsoever arising out of or related

to the modules, including, without limitation, any defects in the modules or from use

or installation. Under no circumstances shall Growatt be liable for incidental ,

consequential or special damages howsoever caused; loss of use, loss of production,

loss of revenues are therefore specifically and without limitation excluded to the

extent legally permissible, Growatt's aggregate liability, if any, in damages or

otherwise, shall not exceed the invoice as paid by the customer.

The “

” described above shall not apply to, and Growatt

shall have no obligation of any kind whatsoever with respect to, any inverter which

has been subjected to:

Misuse, abuse, neglect or accident;

Alteration, improper installation or application;

Unauthorized modification or attempted repairs;

Insufficient ventilation of the product;

Transport damage;

Breaking of the original manufacturers seal;

Non-observance of Growatt installation and maintenance instruction;

Failure to observe the applicable safety regulations

Power failure surges, lighting, flood, fire, exposure to incorrect use,

negligence, accident, force majeure, explosion, terrorist act, vandalism or damage

caused by incorrect installation, modification or extreme weather conditions or other

circumstances not reasonably attributable to Growatt.

The warranty shall also cease to apply if the product cannot be correctly identified as

the product of Growatt. Warranty claims will not be honored if the type of serial

number on the inverters have been altered, removed or rendered illegible.

Limited Product Warranties

14.3 Liability

The liability of Growatt in respect of any defects in its PV inverters shall be limited to

compliance with the obligations as stated in these terms and conditions of warranty.

Maximum liability shall be limited to the sale price of the product. Growatt shall

accept no liability for loss of profit, resultant of indirect damage, any loss of electrical

power and/or compensation of energy  suppliers within the express meaning of that

term.

The warranty rights as meant herein are not transferable or assignable to any third

party excepting the named warranty holder.

14.4 Warranty conditions

If a device becomes defective during the agreed Growatt factory warranty period and

provided that it will not be impossible or unreasonable, the device will be, as selected

by Growatt.

Shipped to a Growatt service centre for repair, or repaired on-site, or exchanged

for a replacement device of equivalent value according to model and age.

The warranty shall not cover transportation costs in connection with the return of

defective modules. The cost of the installation or reinstallation of the modules shall

also be expressly excluded as are all other related logistical and process costs

incurred by all parties in relation to this warranty claim.

Technical Data

15

Technical Data

15

15.1 Specification

47

48

Summary of Contents for 1500-US

Page 1: ...Installation Operation Manual...

Page 2: ...scription 3 1 Inverter Overview 3 2 Information of Label 3 3 Dimensions and weight 3 4 Transportation 3 5 Storage of Inverter Directory 1 2 3 4 1 Unpacking and inspection 1 4 Storage of the manuals 1...

Page 3: ...e connection 7 4 Using shine tool to set the information of the inverter 8 1 Start Up the inverter 8 2 Disconnecting the Inverter 9 1 Checking Heat Dissipation 9 2 Cleaning the Inverter 9 3 Checking t...

Page 4: ...ion and operation of this device Qualified personnel are trained to deal with the dangers and hazards involved in installing electric devices 1 4 Storage of the manuals The manual and other documents...

Page 5: ...he unit Even when the unit is disconnected high contact voltages may still be present within the unit DANGER DANGER Danger of burn injuries due to hot enclosure parts During operation the four sides o...

Page 6: ...nging software parameters with respective communication products e g shinebus or shineNet ect To change the grid relevant parameters you need a personal access code if you need it please contact with...

Page 7: ...1 Phase Inverter Range of input voltage 100 450Vdc Max input short circuit current 15Adc Norminal output power 1650W Range of grid voltage 183 228Vac 208Vac Range of grid frequency 59 3 60 5Hz Normina...

Page 8: ...iciency of 96 Growatt 2000 US Growatt 3000 US CEC efficiency of 96 5 Integrated wire box Integrated DC switch High MPP efficiency of 99 5 Adapt to multi gird model 208Vac 240Vac 277Vac Sound control E...

Page 9: ...her source of energy to it Both AC and DC voltage sources are terminated inside the PV Inverter Please disconnect these circuits before servicing This unit is designed to feed power to the public powe...

Page 10: ...or tilted backwards by max 15 and make sure the connection of inverter must be downwards Never install horizontal and avoids forward and sideways tilt Be sure that the inverter is out of the children...

Page 11: ...h bracket WARNING In order to avoid electrical shock or other injury inspect existing electronic or plumbing installations before drilling holes The dimension of bracket as follow Using the mounting f...

Page 12: ...cket After confirming the inverter is fixed reliably fasten four M6 safety lock sokets head cap screws on the left and right side firmly to prevent the inverter from being lifted off the bracket 5 5 C...

Page 13: ...Connection PV Panel Provide DC power to inverter Converts DC Direct Current power from PV panel to AC Alternating Current power Because Inverter is grid connected it controls the current amplitude ac...

Page 14: ...he local grid standards it is possible to select different connection types The available configurations are shown in the following table NOTE in the inverter wire box AC terminal pin is written as L1...

Page 15: ...he knock out hole and pull the pipe nut slightly feed the cables through the pipe into the wire box till the terminal 2 Open the wire box cover and the knock out hole We suggest the AC separate unit s...

Page 16: ...system are normally ungrounded but will become intermittently grounded without indication when the inverter measures the PV array isolation Because of the transformer less design the DC positive pole...

Page 17: ...exist when the PV panel is exposed to the sun To reduce risk of electric shock avoid touching live components and treat connection terminals carefully 1 Open the independent DC separate unit the DC sw...

Page 18: ...e ratio of true power or watts to apparent power or volt amps They are identical only when current and voltage are in phase than the power factor is 1 0 The power in an ac circuit is very seldom equal...

Page 19: ...er model 2 2 2 The software version The Serial Number 4 The energy today 4 The energy all 4 PV input watt 4 The PV and Bus Votage The grid system 4 Set Language 4 Set LCD Contrast 4 Set Communications...

Page 20: ...he Address model clock to set address Setting grid model choice This function is disable when the inverter work in the normal state you much turn off the AC separate unit and the inverter LCD will dis...

Page 21: ...unication ShineWebbox can simultaneously monitor record and analyze inverter operating parameters real time with a maximum quantity of 50 Monitored data also can be sent to Shine Server Shine Pano 7 1...

Page 22: ...RS485 232 converter PC 7 3 RS485 cable connection 1 Unscrew the plastic connector 2 Make the RS485 cable go through the connector 3 Put two heat shrink tubes onto the front head of RS485 cable 4 Inser...

Page 23: ...atically when the input voltage is higher than 150V 8 2 Disconnecting the Inverter 1 Disconnect the AC circuit breaker and prevent it from being reactivated 2 Turn off the dc switch 3 Check the invert...

Page 24: ...0 minutes before disassembling until the housing has cooled down 3 Screw off all projecting cable glands 4 Lift the inverter off the bracket and unscrew the bracket screws 10 2 Packing the Inverter If...

Page 25: ...rowatt Output High DCI Output current DC offset too high 1 Restart inverter 2 If error message still exists contact Growatt Residual I High Leakage current too high 1 Restart inverter 2 If error messa...

Page 26: ...o low the inverter will also turn to Shutdown Mode De rating Operation 13 De rating Operation 13 Temperature The inverter will monitor the temperature of the heat sink Once the temperature exceeds 75...

Page 27: ...e surges lighting flood fire exposure to incorrect use negligence accident force majeure explosion terrorist act vandalism or damage caused by incorrect installation modification or extreme weather co...

Page 28: ...240 277V ac Max output current 8A 7 8A 6 8A 9 7A 9 4A 8 2A 15A 14 2A 12 3A AC grid frequency range 60Hz 59 3 60 5Hz 60Hz 59 3 60 5Hz 60Hz 59 3 60 5Hz Efficiency Max efficiency 97 97 97 CEC efficiency...

Page 29: ...display LCD LCD LCD Interfaces RS485 RS232 Bluetooth RF Zigbee yes yes opt opt opt yes yes opt opt opt yes yes opt opt opt Warranty 10 years 15 years yes opt yes opt yes opt Certificates and approval...

Page 30: ...hnical problems about our products contact the Growatt Service line We need the following information in order to provide you with the necessary assistance Inverter type Serial number of the inverter...