Input data
Specifications
Growatt
1500-US
Model
Growatt
2000-US
Growatt
3000-US
Max. DC power
1800W
2300W
3200W
Max. DC voltage
450V
500V
500V
Start voltage
150V
150V
150V
DC nominal voltage
360V
360V
360V
PV voltage range
100V-450V
100V-500V
100V-500V
Output data
AC nominal voltage;
range
Default:240V single phase optional:208,240or277 single
phase 183-228@208V 211-264V@240V 244-305@277V
Phase shift (cos
)
φ
1
1
1
THDI
<
3%
<
3%
<
3%
Single phase
Single phase
Single phase
AC connection
MPP voltage range
120V-400V
120V-450V
120V-450V
Number of independent
MPP trackers/strings per
MPP tracker
1/1
1/ 2
1/ 2
Max. input current of
the MPP tracker
12A
14A
17A
Nominal AC
output power
1500W@208V ac
1650W@240&277V ac
1800W@208V ac
2000W@240&277V ac
2500W@208V ac
2800W@240&277V ac
Max. output current
8A/7.8A/6.8A
9.7A/9.4A/8.2A
15A/14.2A/12.3A
AC grid frequency;
range
60Hz;59.3-60.5Hz
60Hz;59.3-60.5Hz
60Hz;59.3-60.5Hz
Efficiency
Max. efficiency
97%
97%
97%
CEC efficiency
96%
96.5%
96.5%
MPPT efficieny
99.5%
99.5%
99.5%
Protection devices
DC reverse polarity
protection
yes
yes
yes
DC switch ratiing for
each MPPT
yes
yes
yes
Output Over current
protection
yes
yes
yes
Output Overvoltage
Protection-varistor
yes
yes
yes
Ground fault monitoring
yes
yes
yes
Grid monitoring
yes
yes
yes
Integrated all - pole sensitive
leakage current monitoring unit
yes
yes
yes
General Data
Dimensions (W / H / D) in
mm
360/465/165
360/465/165
360/465/165
Weight
14.6KG
15.1KG
15.9KG
Operating
temperature
range
-25...+60
(-13...+ 140°F)
with derating above
45°C
113°F
℃
(
)
-25...+60
(-13...+ 140°F)
with derating above
45°C
113°F
℃
(
)
-25...+60
(-13...+ 140°F)
with derating above
45°C
113°F
℃
(
)
Noise emission
(typical)
≤
25 dB(A)
≤
25 dB(A)
≤
25 dB(A)
Altitude
Up to 2000m(6560ft) without power derating
49
50