22 

Function Parameters  

SN 

Name 

Scope 

Introduction 

Default 

Value 

P00.01 

Run command 

model 

0~2 

0: manual operation mode 
1: auto operation mode 

2: communication operation mode 

P00.03 

MAX. Output 

frequency 

P00.04~400.0

0Hz 

The parameter is used to set the maximum 

output frequency of the inverter 

50.00Hz 

P00.04 

Upper limit of 

the running 

frequency  

P00.05~ 

P00.03 

The parameter is the upper limit of the 

output frequency of the inverter which is 
lower than or equal the maximum frequency 

50.00Hz 

P00.05 

Lower limit of 

the running 

frequency 

0.00Hz~ 

P00.04 

If the solar energy is not sufficient to power 
the motor,inverter will drop frequency 
running. The inverter will stop run when the 

running frequency lower than  the lower limit 
frequency 

0Hz 

 

P00.13 

Set direction 

0~2 

0

The inverter runs in the forward 

direction

 

1

The inverter runs in the reverse 

direction

 

2

Forbid to run in reverse 

direction

 

P00.18  Function restore 

parameter 

0~1 

0

No operation 

1

Restore the default value 

P01.08 

Stop mode 

0~1 

0

Decelerate to stop 

1

Coast to stop 

P02.00 

Motor type 

0~1 

0

Three phase motor 

1

Single phase motor 

P02.01 

Rated power of 

asynchronous 

motor 

0.1~ 3000.0kw 

Set this parameter according to rated power 
on the pump nameplate 

NOTE: when resetting the rated power of the 
motor(P02.01),you can initialize the motor 
parameter of (P02.02~P02.05) 

Model 

confirmation 

P02.02 

Rated frequency 
of asynchronous 

motor 

0.01Hz ~ 

P00.03 

Set this parameter according to rated 
frequency on the pump nameplate 

50.00Hz 

P02.04 

Rated voltage of 

asynchronous 

motor 

0 ~ 1200V 

Set this parameter according to rated voltage 
on the pump nameplate 

Model 

confirmation 

P02.05 

Rated current of 

asynchronous 

motor 

0.8 ~ 6000A 

Set this parameter according to rated current 
on the pump nameplate 

Model 

confirmation 

P02.27 

Motor overload 

protection factor 

20.0%~120.0

The pump motor over-load protection factor 

when 
over-load, please refer to the rated current of 
motor to set this parameter.  

100.0% 

P15.00 

PV Inverter 

Selection 

0

Disable 

1

Enabled 

0

means the MPPT function is invalid  

1

means the MPPT function is enabled 

Summary of Contents for 1500TL2-HV

Page 1: ...Solar Pump Inverter 750W 4000W Version 1 3 User Manual...

Page 2: ...it 5 Wiring Introduction 7 Terminal Introduction 7 Assemble DC Connector 8 Assemble AC Output Connector 8 Assemble AC Input Connector 10 Assemble sensor Connector 11 Wiring of Water Level Sensor 12 Re...

Page 3: ...h this document and all safety information Safety Instructions WARNING This chapter contains important safety and operating instructions Read and keep this manual for future reference Inspection If mi...

Page 4: ...res of them 3 When testing water pump be sure to install water pump at appropriate water level Never allow water pump in dry running Otherwise the inverter will activate protection Maintenance 1 Only...

Page 5: ...to set the priority of PV and utility grid input The inverter is suitable for submersible pumps ground pumps swimming pool pumps and other pumps using asynchronous motors Features Rated power 750W to...

Page 6: ...4 Product Overview 1 LCD display 2 LED indicators 3 Function buttons 4 AC input 5 PV input 6 Water level sensor port 7 AC output 8 GPRS WIFI communication port...

Page 7: ...t on a solid metal surface Avoid direct sunlight Be sure the environment is shadyand cool Be sure to install the inverter into a box with waterproofand dustproof Install this inverter at eye level in...

Page 8: ...6...

Page 9: ...AC Output 3 PH motor connect 1 2 L 1 PH motor connect 1 L 1 Connect with motor U phase 2 Connect with motor V phase L Connect with motor W phase PE Connect with protective ground wire COM terminal 1...

Page 10: ...iring Warning Risk of electric shock Before shifting solar panel disconnect the pump inverter AC and DC Besides allow 5 minute internal capacitance discharging Assemble AC Output Connector Connection...

Page 11: ...screw Insert the stripped and bared conductors U V W PE in to screw terminals with sign U V W PE on the socket element and tighten the screws Connect the conductors Push the threaded sleeve in to the...

Page 12: ...pressure screw Insert the stripped and bared conductors L N PE in to screw terminals with sign L N PE on the socket element and tighten the screws Connect the conductors Push the threaded sleeve in to...

Page 13: ...well 7 8 Insert the stripped and bared cable through pressure screw sealing threaded sleeve in sequence insert cables into connection terminal according to number indicates on it and tighten the screw...

Page 14: ...level recovers Wait for 20s then the pump inverter re works normally Notice connect water level sensor 2 to defect whether water is full Connect two signal lines of sensor with 1 and 2 of COM termina...

Page 15: ...4 4 6 1500TL2 HV 7 5A 3PH 10 2A 1PH 220V 1 5 2 5 2 5 6 6 6 6 2200TL2 HV 10A 3PH 14 1PH 220V 2 5 2 5 4 6 6 6 6 4000TL2 HV 16A 3PH 25 1PH 220V 4 4 6 8 8 8 8 Units mm2 Notice The environment temperature...

Page 16: ...ps control Confirm Programming Key 1 Press for a short time to enter programming mode After altering parameter press for a short time to confirm the alteration 2 Press for 2s to enter the programming...

Page 17: ...enter the model setting Click enter again Model Set 3PH Three plase motor Model Set 1PH Single phase motor Long press 3s to set OK Press up and down to select motor type Model Set Set OK Freq Run 50...

Page 18: ...as below Inverter temperature Freq Run 50 00HZ Output frequency of the inverter Freq Set 50 00HZ Set frequency of the inverter PV Volt 350V Input voltage of the inverter PV Power 2000W Input power of...

Page 19: ...alue d Water output test of pump Click the run button to observe the running frequency and water output Under the normal strong light condition if the operation frequency of three phase motor is low o...

Page 20: ...P02 00 0 Setting motor name plate parameters Setting motor name plate parameters P15 29 2 P15 29 1 Automatic switching of photovoltaic input and AC input P15 29 0 Click the run key on the keyboard P00...

Page 21: ...terminal work mode Press the enter key again Change the default value of 1 to 0 Work mode P00 Enter the main parameter modification interface for long press 2s for Enter key Work mode P00 01 Press Ent...

Page 22: ...ed all group parameters will return to the default settings except for group P02 Click enter to set OK to return Power off Long press for 3 seconds to shut down Work mode P00 Enter the main parameter...

Page 23: ...eted return to the main page and press the 3s shutdown key for shut down Power off Work mode P00 Enter the main parameter modification interface for long press 2s for Enter key Model set P02 00 Turn u...

Page 24: ...peration 1 Restore the default value 0 P01 08 Stop mode 0 1 0 Decelerate to stop 1 Coast to stop 0 P02 00 Motor type 0 1 0 Three phase motor 1 Single phase motor 1 P02 01 Rated power of asynchronous m...

Page 25: ...n or equal P15 19 and the current corresponding to the current frequency is less than P15 17 after the time set by P15 16 the inverter will stop run otherwise it will operate normally If the state is...

Page 26: ...n the threshold or the light is weak it can be switched to power frequency input through relay output Note The minimum operation voltage of the system is 60V If the value is 0 the function is disabled...

Page 27: ...load is short circuited Overload Pump Water pump is overload 1 The motor setting rated current is incorrect 2 Input voltage is too low 3 Improper motor s overload protection threshold 4 Motor block o...

Page 28: ...y Lack Water Water shortage Water shortage warning 1 If the water empty alarm function is enabled the device automatically stops after the water empty alarm remains for a certain period of time and no...

Page 29: ...1PH 10A 3PH 14 1PH 16A 3PH 25 1PH Output wiring mode 1P2L 3P3L Output voltage 0 220V Output frequency 0 50 60Hz CONTROL PERFORMANCE Control mode V F Motor type Asynchronous motor 1 Phase 220V 3 Phase...