22
Function Parameters
SN
Name
Scope
Introduction
Default
Value
P00.01
Run command
model
0~2
0: manual operation mode
1: auto operation mode
2: communication operation mode
1
P00.03
MAX. Output
frequency
P00.04~400.0
0Hz
The parameter is used to set the maximum
output frequency of the inverter
50.00Hz
P00.04
Upper limit of
the running
frequency
P00.05~
P00.03
The parameter is the upper limit of the
output frequency of the inverter which is
lower than or equal the maximum frequency
50.00Hz
P00.05
Lower limit of
the running
frequency
0.00Hz~
P00.04
If the solar energy is not sufficient to power
the motor,inverter will drop frequency
running. The inverter will stop run when the
running frequency lower than the lower limit
frequency
0Hz
P00.13
Set direction
0~2
0
:
The inverter runs in the forward
direction
1
:
The inverter runs in the reverse
direction
2
:
Forbid to run in reverse
direction
0
P00.18 Function restore
parameter
0~1
0
:
No operation
1
:
Restore the default value
0
P01.08
Stop mode
0~1
0
:
Decelerate to stop
1
:
Coast to stop
0
P02.00
Motor type
0~1
0
:
Three phase motor
1
:
Single phase motor
1
P02.01
Rated power of
asynchronous
motor
0.1~ 3000.0kw
Set this parameter according to rated power
on the pump nameplate
NOTE: when resetting the rated power of the
motor(P02.01),you can initialize the motor
parameter of (P02.02~P02.05)
Model
confirmation
P02.02
Rated frequency
of asynchronous
motor
0.01Hz ~
P00.03
Set this parameter according to rated
frequency on the pump nameplate
50.00Hz
P02.04
Rated voltage of
asynchronous
motor
0 ~ 1200V
Set this parameter according to rated voltage
on the pump nameplate
Model
confirmation
P02.05
Rated current of
asynchronous
motor
0.8 ~ 6000A
Set this parameter according to rated current
on the pump nameplate
Model
confirmation
P02.27
Motor overload
protection factor
20.0%~120.0
%
The pump motor over-load protection factor
when
over-load, please refer to the rated current of
motor to set this parameter.
100.0%
P15.00
PV Inverter
Selection
0
:
Disable
1
:
Enabled
0
:
means the MPPT function is invalid
1
:
means the MPPT function is enabled
1