23
P15.04 PID Max. Output
Frequency
P15.05~
100.0%
P15.05~100.0%(100% corresponding to
P00.03)
P15.04 is used to limit the Max. value of
target frequency
100.0%
P15.05 PID Min. Output
Frequency
0.0%~P15.04
0.0%~ P15.04(100% corresponding to
P00.03)
P15.05 is used to limit the Min. value of
target frequency
20.0%
P15.13 Full-water delay
0~10000S
Time setting of full-water delay
5S
P15.14
Wake-up delay
when full-Water
0~10000S
During the full-water warning, if the detected
full-water signal is cleared
,
the delay
counts
,
after the time set by P15.14,the
warning is cleared.
20S
P15.16
Operation time
of water pump
Dry-run
0.0~1000.0S
Set the operation time of Dry-run operation.
Under the continuous Dry- run operation
,
the inverter will stop run
,
if the operation
time is reached.
60.0S
P15.17
Current
detection of
automatic Dry-
run protection
0.0~100.0%
0.0%: If it is 0.0%,it is determined by the
inverter
0.1%~100.0%:It is determined by P15.17
100% corresponds to the rated motor
current.
If the target frequency and the absolute
value of the ramp frequency is less than or
equal P15.19,and the current corresponding
to the current frequency is less than P15.17,
after the time set by P15.16, the inverter will
stop run
;
otherwise,it will operate
normally.If the state is not continuous,the
delay counting will be cleared automatically.
50.0%
P15.18
Reset delay of
water pump
Dry- run
0.0~1000.0S
Dry-run protection recovery time.
The operation time and reset time are
counted at the same time
,
It is bigger than
P15.16.After the time set by P15.18-
P15.16
,
the inverter will reset.
120.0S
P15.19
Lag frequency
threshold
0.00~200.00H
z
P15.19 is the lag frequency for the analysis
of Dry-run operation. If the target frequency
and the absolute value of the ramp
frequency is less than or equal P15.19
,
the
current will be compared.
0.50Hz
P15.20
Delay Time of
Weak Light
0.0~3600.0S
If the output frequency is less than or equal
to the lower limit of PI output frequency and
the state lasts for the set value by P15.20,
the inverter will stop run.If the state is not
continuous
,
the delay counting will be
cleared automatically.
NOTE:If the PV voltage is lower than
software undervoltage point
,
it will stop run
and no need to wait for the set time.
If P15.29=0,the system will
switch
to the AC
input when the light is weak.
100.0S