24
P15.21
Delay time of
wake-up at
weak light
0.0~3600.0S
If the PV voltage is higher than the starting
voltage
,
after the delay time
,
it will run
again.
when P15.29=0, if the PV voltage is higher
than 120V,after the delay time
,
it will switch
to solar input model.
300.0S
P15.29 PV input and AC
input selection
0~2
0
:
Automatic input
,
the system will switch
between PV and AC input according to the
detected PV voltage and threshold.
1
:
Forced AC input
2
:
Forced PV input
Threshold setting for switch to AC input.
For models of 220V
:
0.75KW:60.0V
1.5KW~4.0KW:80.0V
For models of 380V
:
2.2KW~5.5KW:180.0V
Threshold setting for switch to PV input.
For models of 220V
:
0.75KW:100.0V
1.5KW~4.0KW:120.0V
For models of 380V
:
2.2KW~5.5KW:240.0V
0
P15.30
Threshold
setting for
switching to
power frequency
0V-P15.31
If the PV voltage is lower than the threshold
or the light is weak,it can be switched to
power frequency input through relay
output.(
Note:
The minimum operation
voltage of the system is 60V.)
If the value is 0,the function is disabled.
The default value depends on
model
.
For models of 220V:
0.75KW:60.0V
1.5KW,2.2Kw and 4KW:80.0V
Depend on
model
P15.31
Threshold
setting for
switching to PV
input
P15.30-400V
If PV voltage is higher than the
threshold
,
after the delay time of P15.21,it can be
switched to PV input through relay output. In
order to avoid repeated switching,the
threshold needs to be higher than the
threshold of P15.30 If the value is 0.0 ,the
function is disabled.
The default value depends on model.
For models of 220V:
0.75KW:100.0V
1.5KW,2.2KW and 4KW:120.0V
Depend on
model
P15.32
Delay Time of
Dry-water
0~10000S
Delay Time setting of dry-water
5S
P15.33
Wake-up delay
time of Dry-
water
0~10000S
During the Dry-water warning
,
if the
detected dry-water signal is cleared
,
the
delay counts
,
after the time set by
P15.33,the warning is cleared.
20S