23
Start voltage
150V
150V
150V
DC nominal voltage
360V
360V
360V
PV range voltage
100V-600V
100V-600V
100V-600V
Number of MPP
trackers/strings per MPP
tracker
1/2
1/2
1/2
Max. input current /per string
12A/12A
15A/15A
15A/15A
Output data
Nominal AC output power
2000W
2500W
3000W
Max. AC power
2000W
2500W
3000W
Nominal output current
8.7A
10.8A
13A
Max. output current
10A
12A
14.3A
AC nominal voltage;range
230V;
207Vac~263Vac
230V;
207Vac~263Vac
230V;
207Vac~263Vac
AC grid frequency;range
50,60HZ;
±
5 Hz
50,60HZ;
±
5 Hz
50,60HZ;
±
5 Hz
Phase shift (cos
φ
)
>0.99
>0.99
>0.99
THDI
<3%
<3%
<3%
AC connection
Single phase
Single phase
Single phase
Efficiency
Max.efficiency
96%
96%
96%
Euro-eta
95.5%
95.5%
95.5%
MPPT efficiency
99.5%
99.5%
99.5%
Protection devices
DC reverse polarity protection
yes
yes
yes
AC short - circuit protection
yes
yes
yes
Ground fault monitoring
Grid monitoring
yes
yes
yes
Integrated all - pole sensitive
leakage current monitoring unit
yes
yes
yes
General Data
Dimensions (W /H /D) in
mm
440/455/135
Weight
14.6KG
15.1 KG
15.9 KG
Operating ambient
temperature range
–25°C…+60°C
–25°C…+60°C
–25°C...+60°C
Continuous full output power
temperature range
–25°C…+45°C
–25°C…+45°C
–25°C…+45°C
Noise emission (typical)
≤
25 dB(A)
≤
25 dB(A)
≤
25 dB(A)
Altitude
Up to 2000m without power derating
Consumption: operating
<5W /< 0.5 W
<5W /< 0.5 W
<5W / <0.5 W