11
Decommissioning
11
11.1. Dismantling the Inverter
11.1. Dismantling the Inverter
1. Disconnect the inverter as described in section 7.
2. Remove all connection cables from the inverter.
CAUTION
Danger of burn injuries due to hot enclosure parts!
Wait 20 minutes before disassembling until the housing has
cooled down.
3. Screw off all projecting cable glands.
4. Lift the inverter off the bracket and unscrew the bracket screws.
11.2. Packing the Inverter
11.2. Packing the Inverter
If possible, always pack the inverter in its original carton and secure it with tension
belts. If it is no longer available, you can also use an equivalent carton. The box must
be capable of being closed completely and made to support both the weight and the
size of the inverter.
11.3. Storing the Inverter
Store the inverter in a dry place where ambient temperatures are always between -
25°C and +60°C.
11.4. Disposing of the Inverter
Do not dispose of faulty inverters or accessories together with household
waste. Please accordance with the disposal regulations for electronic
waste which apply at the installation site at that time. Ensure that the old
unit and, where applicable, any accessories are disposed of in a proper
manner
12
Technical Data
12
12.1. Specification
Table1.GROWATT2500-3000 MTL series
Model
Specifications
Growatt 2500MTL
Growatt 3000MTL
Input data(DC)
Max. DC power
2700W
3200W
Max. DC voltage
500V
500V
Start voltage
150V
150V
PV voltage range
100V-500V
100V-500V
MPP work voltage
range/ nominal voltage
120V-500V/360V
120V-500V/360V
Full load dc voltage
range
190V-450V
190V-450V
Max. input current of
tracker A/ tracker B
10A/10A
10A/10A
Max. input current per
string of tracker
A/tracker B
10A/10A
10A/10A
Number of independent
MPP trackers / strings per
MPP tracker
2/1
2/1
58
59