11.3 Torque Values
Enclosure lid screws
Shell and RS232 screws
AC terminal
M6 socket head cap screws for
securing the enclosure at the bracket
Additional ground screws
Fans screws
1.3Nm(10.8 1bf.in)
0.7Nm(6.2 1bf.in)
1.8Nm(16.0 1bf.in)
2Nm(18 1bf.in)
2Nm(18 1bf.in)
1Nm(9.0 1bf.in)
11.4 Spare Parts and Accessories
In the following table you will find the optional accessories for your product. If
required, you can order these from SHENZHEN GROWATT NEW ENERGY
TECHNOLOGY CO., LTD or your dealer.
Fans
ShineLAN
Wi-Fi
Shine WebBox
Shine Vision receiver
Shine Vision emitter
Internal fan of Growatt TL3
Outside fan of Growatt TL3
Communication interface
Communication interface
Communication data logger
Communication data logger receiver
Communication data logger emitter
025.0006900
025.0007000
025. 0007100
025. 0007200
025. 0007300
MR00.0003100
MR00.0001402
MR00.0001700
MR00.0000201
MR00.0000601
Name
Description
Growatt order number
12
Certificates
Growatt TL3 is designed to use worldwide, hence the inverters meet different safety
standards of variety countries and regions.
Model
Certificates
Growatt 30000-40000 TL3
EN61000-6-2,EN61000-6-3,EN61000-3-2,
EN61000-3-3,EN61000-3-11,EN61000-3-12,
IEC62109-1,IEC62109-2,CE,VDE0126-1-1
,
N4105*
*
Pending
71