5.3.2 Mounting Inverter
5.3.2 Mounting Inverter
WARNING
Falling equipment can cause serious or even fatal injury, never
mount the inverter on the bracket unless you are sure that the
mounting frame is really firmly mounted on the wall after carefully
checking.
After the bracket is firmly mounted on the wall, then mount the inverter on the
bracket.
Rise up the Growatt UE a little higher than the bracket. Considering the weight of
Growatt UE, you need to hang on the inverter. During the process please maintain
the balance of the Growatt UE.
Hang the inverter on the bracket through the match hooks on bracket and the
back of the inverter.
After confirming the inverter is fixed reliably, fasten two M6 soket head cap
screws on the left and right side firmly to prevent the inverter from being lifted
off from the bracket.
17
18
Connecting a Second Protective Conductor
if it is requirement, the earth terminal can be used to connect a second protective
conductor or as equipotential bonding. This prevents touch current if the original
protective conductor fails.
Recommend awning installation, the purpose is to extend the inverter service life
and reduce the power derating of the inverter. The dimension of the awning, refer
to Fig 5.6.