5) Knock the enclosure lid four times to exit setting interface.
You can operate the settings as follow:
a) Setting language
1) Knock the enclosure lid once every time until the text line switch to the text as
follow:
Set language
2) Knock the enclosure lid twice and the text will show the language.
Language: English
3) You can choose the language by tripping the enclosure once; the language
includes English, Deutsh, Espanol, Francais, Italiano.
4) Then you can trip the enclosure three times to confirm the language you have
chosen. And the text line change as follow:
Setting...
Setting. OK
The language is set!
b) Setting Com Address
For the communicating, the inverter needs a communication address. In
multi system, the addresses of inverters must be different from one to
another.
43
44
1) Single knock until the text line switch to the text as follow:
Com Address: 001
2) Double knock the enclosure lid and the lower number text”1” will flash: 001.
Com Address: 002
3) If you want to change it, single knock to change it from 0 to 9.
4) If you want to set the address more lager, double knock the enclosure lid to let the
higher number text “002” flashing. And single knock the enclosure lid to change it
from 0 to 9. So as the highest number text. In the general condition, the maximum
number of the address is within 32.
Com Address: 012
5) Then you can knock the enclosure three times to confirm the address you have set.
Setting...
Setting. OK
The Com Address is set!
C) Switching the RS232 and the External wireless communication
As the Serial communication with the computer and the external
wireless communication using the same serial port, we have to choose
one. The RS232 is communicating to computer so that the computer can
be connected to the inverter using our software tools. The RS232 is
chose by default in the inverter.