CAUTION:
connect the utility to “AC Output Connector”.
CAUTION: Be sure to connect L terminal of load to L terminal of “AC Output
Connector” and N terminal of load to N terminal of “AC Output Connector”. The G
terminal of “AC Output Connector” is connected to grounding of the load. Do NOT
mis-connect.
CAUTION: This inverter is not allowed to operate in parallel. Please do NOT parallel
connect more than one unit in AC output connector. Otherwise, it will damage this
inverter.
It’s only allowed to connect load to “AC Output Connector”. Do NOT
Please set up mains output in parameter setting of bundled software. When
“Emergency power supply control” is enabled and inverter is working in battery
mode, it will cut off AC output and remain energy through EMS port when battery
voltage drops down to the setting value in “Battery voltage to cut-off mains output
in battery mode”. After that, if battery voltage recovers to the setting value in
“Battery voltage to turn on mains output in battery mode”, inverter will turn on AC
output again.