9
Position
Description
A/B
PV modules
C
Circuit breaker
D
Growatt Inverter
E
Energy meter
F
Utility grid
The inverter may only be operated with a permanent connection to the public power grid. The
inverter is not intended for mobile use. Any other or additional use is not considered the intended
use. The manufacturer/supplier is not liable for damage caused by such unintended use. Damage
caused by such unintended use is at the sole risk of the operator.
PV modules Capacitive Discharge Currents
PV modules with large capacities relative to earth, such as thin-film PV modules with cells on a
metallic substrate, may only be used if their coupling capacity does not exceed
470nF
. During
feed-in operation, a leakage current flows from the cells to earth, the size of which depends on the
manner in which the PV modules are installed (e.g. foil on metal roof) and on the weather (rain,
snow). This "normal" leakage current may not exceed 50mA due to the fact that the inverter would
otherwise automatically disconnect from the electricity grid as a protective measure.
2.2 Qualification of skilled person
This grid-tied inverter system operates only when properly connected to the AC -distribution
network. Before connecting the Growatt MTL-S to the power distribution grid, contact the local
power distribution grid company. This connection must be made only by qualified technical
personnel to connect, and only after receiving appropriate approvals, as required by the local
authority having jurisdiction.
2.3 Safety instruction
The GROWATT MTL-S Inverters is designed and tested according to international safety
requirements
(
IEC62109-1,CE, AS4777
)
; however, certain safety precautions must be observed
when installing and operating this inverter. Read and follow all instructions, cautions and warnings
in this installation manual. If questions arise, please contact Growatt’s technical services at +86
(0)755 2747 1942.