2.6 Operation Warnings
Growatt inverter away from children.
WARNING
Make all electrical connections (e.g. conductor termination, fuses, PE
connection, etc.) in accordance with prevailing regulations. When working
with the inverter powered on, adhere to all prevailing safety regulations to
minimize risk of accidents.
Systems with inverters typically require additional control (e.g., switches,
disconnects) or protective devices (e.g., fusing circuit breakers) depending
upon the prevailing safety rules.
CAUTION
The Growatt Inverter converts DC Current from PV generator into AC
current. The inverter is suitable for mounting indoors and outdoors.
You can use the AC current gernerated as follows:
House grid:
Energy flows into the house grid. The consumers connected,
for example, household devices or lighting, consume the
energy. The energy left over is fed into the public grid. When
the Growatt is not gernerating any energy, e.g., at night, the
consumers which are connected are supplied by the public
grid.The Growatt does not have its own energy meter. When
energy is fed into the public grid, the energy meter spins
backwards.
Public grid:
Energy is fed directly into the public grid. The Growatt is
connected to a separate energy meter. The energy produced is
compensated at a rate depending on the electric power
company.