18
5.2 Selecting the installation location
This is guidance for installer to choose a suitable installation location, to
avoid potential damages to device and operators.
The installation location must be suitable for the inverter's weight and
dimensions for a long period time.
Select the installation location so that the status display can be easily viewed.
Do not install the inverter on structures constructed of flammable or
thermolabile materials.
Never install the inverter in environment of little or no air flow, nor dust
environment. That may derate the efficiency of the cooling fan of the
inverter.
The Ingress Protection rate is IP65 which means the inverter can be installed
outdoors and indoors.
The humidity of the installation location should be 0~100% without
condensation.
The installation location must be freely and safely to get at all times.
Vertically installation and make sure the connection of inverter must be
downwards. Never install horizontal and avoids forward and sideways tilt.
Be sure that the inverter is out of the children’s reach.
Don’t put any things on the inverter. Do not cover the inverter.
Do not install the inverter near television antenna or any other antennas and
antenna cables.
Inverter requires adequate cooling space. Providing better ventilation for the
inverter to ensure the heat escape adequately. The ambient temperature