Growatt New Energy.CO.LTD
www.ginverter.com
15
the inverter components will be exposed to considerable stress. Frequent use of the AC switch will
lead to damage of the inverter.
Machine high-power grid, rigorous direct disconnect DC and AC circuit breaker, this may lead to
permanent damage of the AC and DC circuit breakers, more serious may cause permanent damage
to the internal components of inverter
Emergency STOP
CAUTION
The emergency stop button is only used in case of emergency, such as: serious failure in the grid,
fire, etc
Figure 3
‐
3
‐
1
‐
3 Emergency STOP
The emergency stop button immediately disconnects the inverter from both grid and PV arrays,
which ensure the safety of the inverter. By pressing the emergency stop button, the device will be
locked in the "off" position. Only release the emergency stop button by rotating it clockwise and
closing AC, DC breaker, can the inverter resume working normally.
On-off knob
It is used to start or stop the inverter.