Growatt New Energy.CO.LTD
www.ginverter.com
19
repair the inverter, and you should get in touch with the local dealers or call Growatt customer
service department for help.
3.5 Protection
Anti-islanding
When the local power grid shutdown due to malfunction or maintenance of equipment, the
inverter will be physically cut off the connection to the grid, in order to protect operating
personnel working in the electricity grid, and the inverter is in compliance with the relevant
standards.
Lightning protection
Inverter built-in lightning protection module has the DC / AC side lightning over-voltage
protection to avoid inverter from being damaged.
More protection features, please refer to the section 6.3.
3.6 Storage
If there is a long time before installation or operation, the Growatt CP 100 should be stored
appropriately.
The packaging should be restored to its original state;
Retain the desiccant in the packaging.
The Growatt CP 100 can only be stored when it is stopped and all the doors are closed in a
dry room to protect the internal circuits against dust and moisture.
Storage temperature range: -40~55
℃
Storage relative humidity range: 5 %~95 %
Operating temperature range: -25~55
℃
Operating relative humidity range:5 %~95%
Max. altitude:2000 m