4 Products installation
4.1 Installation condition requirements
To ensure normal operation of the machine, the installation environment is required as follows:
The ingress protection of inverter is IP20. Moreover, as this product is an electronic
equipment, it shall not be placed in humid environment;
Install indoors and avoid sunlight and rain;
Ventilation of the room shall be good;
The installation environment shall be clean;
As some noise will be produced in operation, this equipment shall be installed far from
residential quarters;
The installation ground shall be even enough, and firm enough to support the weight of
inverter;
The installation position shall be convenient for maintenance;
Ambient temperature range: –25°C
~
55°C;
Appropriate space shall be reserved for the machine to ensure ventilation and cooling.
We suggest inverter is installed in the distribution room. The floor, wall clearance, Ventilation
equipment and precaution should be designed by professional personnel and satisfy the following
requirements.
[Foundation requirement]
Inverter is required to install on even ground with fire-retardant material as the surface or channel
steel support structure, and sag or tilt ground is prohibited. The foundation shall be solid, safe and
reliable. The foundation shall be capable of bearing the load of the inverter. Its load bearing ability
shall be concerned throughout the installation place selection.
[Clearance space]
During installation of the inverter, appropriate space shall be left to the wall or other equipments,
in order to satisfy the requirements on narrowest maintenance channel, emergency access and
ventilation.
In front of the installation place of inverter, a space of 1.5m or more shall be ensured, the back