Growatt New Energy.CO.LTD
www.ginverter.com
38
4.5 Communication
The inverter of Growatt CP series has various communication methods. When the user needs to
monitor the operating status of PV power generation system, we provide single-machine and
multi-machine control programs, and diversified communication interfaces for customer's
selection.
4.5.1 RS485 communication
The inverter, through RS485 tandem, is connected with the PC for communication through
RS485/RS232 adaptor. Inside the PC, a multi-machine monitoring software ShineNet
independently developed by the Growatt is monitoring in real time the operating status of all
inverters, as shown in Figure 4-5-1. The RS485 wire should be less than 1000m.
Figure
RS485 Multi-machine Communication
4.6 Installation inspection
Before the inverter is put into operation, it shall be inspected for installation. Two working men or
more shall inspect to ensure correct installation of all installation according to the following table.
Mechanical Installation Items Inspection
□
No deformation and damage to inverter.
□
Inverter's bottom is fixed, and the support is stable and reliable.
□
Enough space is left around inverter.
□
The ambient temperature, humidity and ventilation satisfy requirements.
□
Smooth flow of cooling air.
□
Complete and reliable sealing protection of cabinet.