Communication

5.1 Communications software instructions

ShineNET  is  a  PC  software  that  communicates  with  Shine  Inverter  to  analyze  the 
inverter work state. It is convenient for you to know the inverter real time working 
state and the history work information.

Spec:

1.

Communicate with inverter by RS232 and Bluetooth.

2.

Construct  net  with  inverter,  GROmonitor  and  ShineNet  by  RS232,  Bluetooth 

and Internet.

3.

Two Interfaces: Multi Inverter Interface and Wave Data Interface.

4.

In Multi Inverter Interface: 9 inverters working data at the same time, you can 

select your own compare inverters and parameters.

5.

In  Wave  Data  Interface:  Query  the  inverter  real  time  and  history  power  wave, 

work data and error information.

6.

Multi  languages:  English,  Simple  Chinese,  French,  German,  Spanish  and  etc.         

Support OS: WinXP / Vista / win7 / 2000/ 2003

5.2 Monitor

After  setting  the  software  the  user  can  monitor  the  inverter.  The  right  side  of  the 
main interface is the detailed information of inverter.

5.3 Detailed information

Detailed setting method and other functions refer to “ShineNET Manual.” in the CD.

Trouble Shooting 

6

In  most  situations,  the  Inverter  requires  very  little  service.  However,  if  Inverter  is  not 
able  to  work  perfectly,  please  refer  to  the  following  instructions  before  calling  your 
local dealer.
Should any problems arise, the LED on the front panel will be red and the LCD displays 
the relevant information. Please refer to the following for a list of potential problems 
and their solutions.

SYSTEM FAULT

Ground I Fault

Isolation Fault

Grid Fault

1. The ground current is too high.
2. Unplug the inputs from the PV generator and check the peripheral AC system.
3. After the cause is cleared, re-plug the PV panel and check PV-Inverter status.
4. If the problem persists please call service.

1. Check the impedance is between PV (+) & PV (-) and the PV-Inverter is earthed. 
The impedance must be greater than 8M.
2. If the problem persists please call service.

1. Wait for 5 minutes, if the grid returns to normal, PV-Inverter automatically restarts.
2. Make sure grid voltage and frequency meet the specifications.
3. If the problem persists please call service.
4. Check grid usability.

No AC connection

1. Grid is not connected.
2. Check grid connection cables.

INVERTER FAILURE

PV Over Voltage

Consistent Fault

1.  Check  the  open  PV  voltage;  see  if  it  is  greater  than  or  too  close  to  500VDC.
2. If PV voltage is less than 500VDC, and the problem still occurs, please call local service.

1. Disconnect PV (+) or PV (-) from the input, restart the PV-Inverter.
2. If it does not work, call service.
If there is no display on the panel, please check PV-input connections. If the voltage is 

higher than 150V, call your local service.

During periods of little or no sunlight, the PV-Inverter may continuously start up and 

shut  down.  This  is  due  to  insufficient  power  generated  to  operate  the  control 

circuits.

Summary of Contents for Growatt 1500

Page 1: ...service ginverter com GR UM 001 07 GROWATT NEW ENERGY CO LTD ...

Page 2: ...of this unit first check this manual before contacting your local dealer or representative Instructions inside this manual will help you solve most installation and operation difficulties CONTRNT INSTALLATION 2 1 Installation manual 2 2 Fixed on the wall 2 3 Connect to the grid AC utility 2 4 Connect to PV panel DC input 2 5 Checking 2 6 System diagram MODES OF OPERATION 3 1 Normal mode 3 2 Fault ...

Page 3: ...a DC voltage When connected to this equipment a photovoltaic panel will charge the DC link capacitors Energy stored in this equipment s DC link capacitors presents a risk of electric shock Even after the unit is disconnected from the grid and photovoltaic panels high voltages may still exist inside the PV Inverter Do not remove the casing until at least 10 minutes after disconnecting all power sou...

Page 4: ... ensure it fits on to the bracket Insert safety lock screws to the bottom leg to secure the inverter image 3 Check the secure mounting of the PV Inverter by trying to raise it from the bottom The PV Inverter should remain firmly attached Select the installation location so that the status display can be easily viewed Choose a strong mounting wall to prevent vibrations while inverter is operating 4...

Page 5: ...reat connection terminals carefully D 2 4 Connect to PV panel DC input 2 5 Checking 6 7 2 5 1 Country selecting When the PV panels are connected and their output voltage is greater than 100Vdc but the AC grid is not yet connected inverter will start up automatically If it is the first time to power on the inverter after installation you may need to select a specific country Otherwise the interface...

Page 6: ...ctful please contact Growatt for specific software to clear and reset again When the selection is successful the inverter will reboot automatically 2 5 2 Commissioning After the inverter reboot LCD will produce the following messages in order Ser NO xxx xxxxx FW version Waiting No AC connection the display repeats NO Utility and LED will be red Close the AC breaker or fuse between PV Inverter and ...

Page 7: ...t controller can continuously monitor and adjust the system status If Inverter finds any unexpected conditions such as grid problems or internal failure it will display the information on its LCD and the LED will be red 3 3 Shutdown mode During periods of little or no sunlight Inverter automatically stops running In this mode Inverter does not take any power from the grid The display and LED s on ...

Page 8: ... auto test Update Software The second line of LCD SerNo CYCLE DISPLAY DISPLAY TIME S REMARK 1 2 3 4 5 6 7 8 9 10 11 12 13 Etoday xx x KWh Eall xxx x KWh Tall xx x h PV xxx xxx B xxx AC xxxV F xx xHz SerNo xxxxxxxxxx Module PX UX MX SX FW version x x x Enable Auto Test Set Language Set LCD Contrast System F XXHz COM address xx 4 4 4 4 4 4 4 4 4 4 4 4 4 The energy today The total energy The total wo...

Page 9: ...he Frequency you need and wait until the display become dark Set contrast Knock to make the display bright knock to COM Address xx double knock to change the Address model knock to set address Inverter Status 4 Inverter is designed to be user friendly therefore the status of the Inverter can be easily understood by reading the information shown on the front panel display All possible messages are ...

Page 10: ...LED on the front panel will be red and the LCD displays the relevant information Please refer to the following for a list of potential problems and their solutions SYSTEM FAULT Ground I Fault Isolation Fault Grid Fault 1 The ground current is too high 2 Unplug the inputs from the PV generator and check the peripheral AC system 3 After the cause is cleared re plug the PV panel and check PV Inverter...

Page 11: ...rent per string Max DC voltage Max DC power PV voltage range MPP voltage range Number of MPP trackers strings per MPP tracker 20A 20A 4200W 580V 100V 580V 250V 500V 1 3 20A 20A 4600W 580V 100V 580V 250V 500V 1 3 20A 20A 5000W 5200W 580V 100V 580V 250V 500V 1 3 Output Data AC connection Efficiency MPPT efficiency Nominal AC output power Max AC power Max output current AC nominal voltage range AC gr...

Page 12: ...s yes yes yes 360 329 132 11 5 KG 360 329 132 11 7 KG 360 329 132 12 2 KG Operating temperature range 25 C 60 C 25 C 60 C 25 C 60 C Continuous full output power temperature range 25 C 50 C 25 C 50 C 25 C 50 C Noise emission typical 25 dB A 25 dB A 25 dB A Sungold 3000 Sungold 5000 20A 20A 5200W 580V 100V 580V 250V 500V 1 3 Single phase 1650W 1650W 8A 230V 207Vac 263Vac 50Hz 60Hz 5Hz 1 3 Single pha...

Reviews: