18
19
Specifications
7
Input Data
Max. input current
/per string
Max. DC voltage
Max. DC power
PV voltage range
MPP voltage range
Number of MPP trackers/
strings per MPP tracker
Growatt1500
10A/10A
1800W
450V
100V-450V
175V-450V
1 / 1
Growatt2000
12A/12A
2300W
500V
100V-500V
195V-450V
1 / 2
15A/15A
3200W
500V
100V-500V
250V-450V
1 / 2
Output Data
AC connection
Efficiency
MPPT efficiency
Nominal AC output power
Max. AC power
Max. output current
AC nominal voltage; range
AC grid frequency ; range
Phase shift (cos
φ
)
THDI
Max . efficiency
Euro-eta
99.5%
97%
96.5%
99.5%
97%
96.5%
99.5%
97%
96.5%
Protection Devices
Integrated all-pole sensitive
leakage current monitoring unit
General Data
DC reverse polarity protection
AC short-circuit protection
Ground fault monitoring
Grid monitoring
Dimensions (W / H / D) in mm
Weight
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
360/329/132
11.5 KG
360/329/132
11.7 KG
360/329/132
12.2 KG
Operating temperature range
–25°C..+60°C
–25°C..+60°C
–25°C..+60°C
Continuous full output power
temperature range
–25°C..+50°C
–25°C..+50°C
–25°C..+50°C
Noise emission (typical)
≤
25 dB(A)
≤
25 dB(A)
≤
25 dB(A)
Growatt3000
Single phase
1600W
1650W
8A
220,230,240V;
180Vac-280Vac
50Hz,60Hz;
±
5Hz
1
< 3%
Single phase
2000W
2200W
11A
220,230,240V;
180Vac-280Vac
50Hz,60Hz;±5Hz
1
< 3%
Single phase
2850W
3000W
15A
220,230,240V;
180Vac-280Vac
50Hz,60Hz;±5Hz
1
< 3%
yes
yes
yes
yes
yes
Consumption: operating
(standby) / night
Topology
<5W /< 0.5 W
transformerless
<5W /< 0.5 W
transformerless
<5W /< 0.5 W
transformerless
Cooling concept
No fan
No fan
No fan
Installation: Indoor/
Outdoors (IP65 electronics)
yes / yes
yes / yes
yes / yes
Input Data
Growatt4000
Growatt4400
Growatt5000
Max. input current
/per string
Max. DC voltage
Max. DC power
PV voltage range
MPP voltage range
Number of MPP trackers/
strings per MPP tracker
20A/20A
4200W
580V
100V-580V
250V-500V
1 / 3
20A/20A
4600W
580V
100V-580V
250V-500V
1 / 3
20A/20A
5000W/5200W
580V
100V-580V
250V-500V
1 / 3
Output Data
AC connection
Efficiency
MPPT efficiency
Nominal AC output power
Max. AC power
Max. output current
AC nominal voltage; range
AC grid frequency ; range
Phase shift (cos
φ
)
THDI
Max . efficiency
Euro-eta
99.5%
97.8%
97.4%
99.5%
97.8%
97.4%
99.5%
97.8%
97.4%
Protection Devices
Integrated all-pole sensitive
leakage current monitoring unit
General Data
DC reverse polarity protection
AC short-circuit protection
Ground fault monitoring
Grid monitoring
Dimensions (W / H / D) in mm
Weight
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
406/406/192
21 KG
406/406/192
21KG
406/406/192
21 KG
Operating temperature range
–25°C..+60°C
–25°C..+60°C
–25°C..+60°C
Continuous full output power
temperature range
–25°C..+50°C
–25°C..+50°C
–25°C..+50°C
Noise emission (typical)
≤
25 dB(A)
≤
25 dB(A)
≤
25 dB(A)
Single phase
3680W
4000W
16A
220,230,240V;
180Vac-280Vac
50Hz,60Hz;
±
5Hz
1
< 3%
Single phase
4200W
4400W
21A
220,230,240V;
180Vac-280Vac
50Hz,60Hz;±5Hz
1
< 3%
Single phase
4600W
4600W/5000W
22.7A
220,230,240V;
180Vac-280Vac
50Hz,60Hz;±5Hz
1
< 3%
yes
yes
yes
yes
yes
Consumption: operating
(standby) / night
Topology
<5W /< 0.5 W
transformerless
<5W /< 0.5 W
transformerless
<5W /< 0.5 W
transformerless
Cooling concept
No fan
No fan
No fan
Installation: Indoor/
Outdoors (IP65 electronics)
yes / yes
yes / yes
yes / yes
*
Optionally provide 5000W
*
*
EN50178, VDE0126-1-1, EN61000-3-2, EN61000-6-1,
EN61000-6-2, EN61000-6-3, EN61000-6-4, IEC-62109,DK5940,
G83,RD1663, VDE-AR-N4105, CEI 0-21
CE / TUV,
Certificates and Approvals
EN50178, VDE0126-1-1, EN61000-3-2, EN61000-6-1,
EN61000-6-2, EN61000-6-3, EN61000-6-4, IEC-62109,DK5940,
G83,RD1663
CE / TUV,
Certificates and Approvals