background image

20

Input Data

Max. input current 
/per string

Max. DC voltage

Max. DC power

PV voltage range 

MPP  voltage range

Number of MPP trackers/

strings per MPP tracker

Sungold 1500

10A/10A

1800W

450V

100V-450V

175V-450V

1 / 1

Sungold 2000

12A/12A

2300W

500V

100V-500V

195V-450V

1 / 2

15A/15A

3200W

500V

100V-500V

250V-450V

1 / 2

Output Data

AC connection

Efficiency

MPPT efficiency

Nominal AC output power 

Max. AC power

Max. output current

AC nominal voltage;range

AC grid frequency ; range

Phase shift (cos 

φ

THDI 

Max . efficiency

Euro-eta

99.5%

97%

96.5%

99.5%

97%

96.5%

99.5%

97%

96.5%

Protection Devices

Integrated all-pole sensitive 

leakage current monitoring unit

General Data

DC reverse polarity protection

AC short-circuit protection

Ground fault monitoring

Grid monitoring

Dimensions (W / H / D) in mm

Weight

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

360/329/132

11.5 KG

360/329/132

11.7 KG

360/329/132

12.2 KG

Operating temperature range

–25°C..+60°C

–25°C..+60°C

–25°C..+60°C

Continuous full output power 
temperature range

–25°C..+50°C

–25°C..+50°C

–25°C..+50°C

Noise emission (typical)

≤ 

25 dB(A)

≤ 

25 dB(A)

≤ 

25 dB(A)

Sungold 3000

Sungold 5000

20A/20A

5200W

580V

100V-580V

250V-500V

1 / 3

Single phase

1650W

1650W

8A

230V; 
207Vac~263Vac

50Hz,60Hz;±5Hz

1

< 3%

Single phase

2000W

2200W

11A

230V; 
207Vac~263Vac

50Hz,60Hz;±5Hz

1

< 3%

Single phase

2850W

3000W

15A

230V; 
207Vac~263Vac

50Hz,60Hz;±5Hz

1

< 3%

Single phase

4600W

5000W

22.7A

230V; 
207Vac~263Vac

50Hz,60Hz;±5Hz

1

< 3%

99.5%

97.8%

97.4%

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

406/406/192

21 KG

–25°C..+60°C

–25°C..+50°C

≤ 

25 dB(A)

Consumption: operating 

(standby) / night

Topology

<5W /< 0.5 W

transformerless

<5W /< 0.5 W

transformerless

<5W /< 0.5 W

transformerless

Cooling concept

No fan

No fan

No fan

yes / yes

yes / yes

yes / yes

<5W /< 0.5 W

transformerless

No fan

yes / yes

Installation: Indoor/
Outdoors (IP65 electronics)

Certificates and Approvals

As4777, AS/NZS 3100

Summary of Contents for Growatt 1500

Page 1: ...service ginverter com GR UM 001 07 GROWATT NEW ENERGY CO LTD ...

Page 2: ...of this unit first check this manual before contacting your local dealer or representative Instructions inside this manual will help you solve most installation and operation difficulties CONTRNT INSTALLATION 2 1 Installation manual 2 2 Fixed on the wall 2 3 Connect to the grid AC utility 2 4 Connect to PV panel DC input 2 5 Checking 2 6 System diagram MODES OF OPERATION 3 1 Normal mode 3 2 Fault ...

Page 3: ...a DC voltage When connected to this equipment a photovoltaic panel will charge the DC link capacitors Energy stored in this equipment s DC link capacitors presents a risk of electric shock Even after the unit is disconnected from the grid and photovoltaic panels high voltages may still exist inside the PV Inverter Do not remove the casing until at least 10 minutes after disconnecting all power sou...

Page 4: ... ensure it fits on to the bracket Insert safety lock screws to the bottom leg to secure the inverter image 3 Check the secure mounting of the PV Inverter by trying to raise it from the bottom The PV Inverter should remain firmly attached Select the installation location so that the status display can be easily viewed Choose a strong mounting wall to prevent vibrations while inverter is operating 4...

Page 5: ...reat connection terminals carefully D 2 4 Connect to PV panel DC input 2 5 Checking 6 7 2 5 1 Country selecting When the PV panels are connected and their output voltage is greater than 100Vdc but the AC grid is not yet connected inverter will start up automatically If it is the first time to power on the inverter after installation you may need to select a specific country Otherwise the interface...

Page 6: ...ctful please contact Growatt for specific software to clear and reset again When the selection is successful the inverter will reboot automatically 2 5 2 Commissioning After the inverter reboot LCD will produce the following messages in order Ser NO xxx xxxxx FW version Waiting No AC connection the display repeats NO Utility and LED will be red Close the AC breaker or fuse between PV Inverter and ...

Page 7: ...t controller can continuously monitor and adjust the system status If Inverter finds any unexpected conditions such as grid problems or internal failure it will display the information on its LCD and the LED will be red 3 3 Shutdown mode During periods of little or no sunlight Inverter automatically stops running In this mode Inverter does not take any power from the grid The display and LED s on ...

Page 8: ... auto test Update Software The second line of LCD SerNo CYCLE DISPLAY DISPLAY TIME S REMARK 1 2 3 4 5 6 7 8 9 10 11 12 13 Etoday xx x KWh Eall xxx x KWh Tall xx x h PV xxx xxx B xxx AC xxxV F xx xHz SerNo xxxxxxxxxx Module PX UX MX SX FW version x x x Enable Auto Test Set Language Set LCD Contrast System F XXHz COM address xx 4 4 4 4 4 4 4 4 4 4 4 4 4 The energy today The total energy The total wo...

Page 9: ...he Frequency you need and wait until the display become dark Set contrast Knock to make the display bright knock to COM Address xx double knock to change the Address model knock to set address Inverter Status 4 Inverter is designed to be user friendly therefore the status of the Inverter can be easily understood by reading the information shown on the front panel display All possible messages are ...

Page 10: ...LED on the front panel will be red and the LCD displays the relevant information Please refer to the following for a list of potential problems and their solutions SYSTEM FAULT Ground I Fault Isolation Fault Grid Fault 1 The ground current is too high 2 Unplug the inputs from the PV generator and check the peripheral AC system 3 After the cause is cleared re plug the PV panel and check PV Inverter...

Page 11: ...rent per string Max DC voltage Max DC power PV voltage range MPP voltage range Number of MPP trackers strings per MPP tracker 20A 20A 4200W 580V 100V 580V 250V 500V 1 3 20A 20A 4600W 580V 100V 580V 250V 500V 1 3 20A 20A 5000W 5200W 580V 100V 580V 250V 500V 1 3 Output Data AC connection Efficiency MPPT efficiency Nominal AC output power Max AC power Max output current AC nominal voltage range AC gr...

Page 12: ...s yes yes yes 360 329 132 11 5 KG 360 329 132 11 7 KG 360 329 132 12 2 KG Operating temperature range 25 C 60 C 25 C 60 C 25 C 60 C Continuous full output power temperature range 25 C 50 C 25 C 50 C 25 C 50 C Noise emission typical 25 dB A 25 dB A 25 dB A Sungold 3000 Sungold 5000 20A 20A 5200W 580V 100V 580V 250V 500V 1 3 Single phase 1650W 1650W 8A 230V 207Vac 263Vac 50Hz 60Hz 5Hz 1 3 Single pha...

Reviews: