Output Data
AC connection
Efficiency
MPPT efficiency
Nominal AC power
Nominal output current
Max. output current
AC voltage range
AC grid frequency range
Phase shift (cos
φ
)
at full load
THDI at full load
Max . efficiency
Euro-eta
Single phase
99.5%
3600W
15.6A
18A
220V / 230V / 240V
180V - 280V
50Hz,60Hz/±5Hz
1
<3%
97.6%
97%
Single phase
99.5%
4200W
18.5A
21A
220V / 230V / 240V
180V - 280V
50Hz,60Hz/±5Hz
1
<3%
97.9%
97.4%
Single phase
99.5%
4600W/5000W
20A
25A
220V / 230V / 240V
180V - 280V
50Hz,60Hz/±5Hz
1
<3%
97.9%
97.4%
3600MTL
4200MTL
5000MTL
Protection Devices
Integrated all-pole sensitive
leakage current monitoring unit
General Data
DC reverse polarity protection
AC short-circuit protection
Ground fault monitoring
Grid monitoring
Dimensions (W / D / H) in mm
Weight
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
360/510/188
24 KG
360/510/188
24 KG
360/510/188
24 KG
Operating ambient temperature
range
–25°C..+60°C
–25°C..+60°C
–25°C..+60°C
Continuous full output power
temperature range
–25°C..+50°C
–25°C..+50°C
–25°C..+50°C
Protection degree
IP 65
IP 65
IP 65
Outdoor/Indoor
yes / yes
yes / yes
yes / yes
Noise emission (typical)
≤
25 dB(A)
≤
25 dB(A)
≤
25 dB(A)
26
27
Features
Warranty:5years/10years
Load Curve
In different input voltage
case, the power can be
handled by each MPP tracker
Efficiency Curve
DC connection:
MC3/MC4/H4
LCD displqy
Interfaces:
Bluetooh/RS485/RS232
yes / opt
opt / opt / yes
yes
opt / opt / yes
yes / opt
opt / opt / yes
yes
opt / opt / yes
yes / opt
opt / opt / yes
yes
opt / opt / yes
Cooling concept
Topology
3600MTL
4200MTL
5000MTL
No fan
transformerless
No fan
transformerless
No fan
transformerless
Altitude
XX
Humidity
XX
Up to 2000m without
power derating
Up to 2000m without
power derating
Up to 2000m without
power derating
0 ~ 95%, no
condensation
0 ~ 95%, no
condensation
0 ~ 95%, no
condensation
Overvoltage category
Ⅲ
Ⅲ
Ⅲ
Consumption: operating
(standby) / night
<5W /< 0.5 W
<5W /< 0.5 W
<5W /< 0.5 W
General Data
Optionally provide 5000W