Connecting Meter
4.
Shenzhen Growatt New Energy Technology CO.,LTD
No.28 Guangming Road, Shiyan Street, Bao’an District,
Shenzhen, P.R.China
No.28 Guangming Road, Shiyan Street, Bao’an District,
Shenzhen, P.R.China
GR
-
UM
-
193
-
A
-
01
+86 0755 2747 1942
+86 0755 2747 1942
www.ginverter.com
www.ginverter.com
T
E
W
service@ginverter.com
service@ginverter.com
Download
Manual
Growatt New Energy
The following table describes how we can connect EASTRON meter (SDM230-Modbus) to inverter:
The following table describes how we can connect CHINT meter (DDSU666) to inverter:
Meter Pin NO.
Description
Meter Connection
1
2
3
4
7
8
L-in
L-out
N-in
N-out
RS485A
RS485B
Grid L
COM Pin 7 RS485A2
COM Pin 8 RS485B2
Inverter L & Load L
Grid N
Inverter N & Load N
Inverter L & Load L
Grid N
Inverter N & Load N
Meter Pin NO.
Description
Meter Connection
1
2
3
4
5
6
L-in
L-out
N-in
N-out
RS485A
RS485B
Grid L
COM Pin 7 RS485A2
COM Pin 8 RS485B2
Verifying the Installation
1.The MIC TL-X series is installed correctly and securely.
2.The Monitor is installed correctly and securely.
3.The Ground cable is connected correctly and securely.
4.The DC switch and all the switches connecting to the MIC TL-X series are OFF.
5.The AC output power cable, DC input power cable and signal cable are connected correctly and securely.
6.Unused terminals and ports are locked by watertight caps.
5.
Powering On the System
Step1: Turn on the AC switch between the MIC TL-X series and the
power grid.
Step2: Turn on the DC switch at the bottom of the MIC TL-X series.
Step3: When the OLED show ”Set country”, Please Set the country
follow the below step otherwise skip all steps.
Set
Country
xxxxxxxx
Step4: Single touch to switch Country, such as
Set
Country
Newzealand
Step5:
Press the touch key for 5s,the OLED shows Country setting is
complete.
Set
OK
Touch button
Single touch
Double touch
Three touch
Hold 5s
Description
Switch display or 1
Enter
Previous menu
Confirm Country setting or
Number recover default value
6.
Tips:
1.If the LED light is green, the system is operating normally.
2.You can reset the country by “Set Country” in the submenu of “Set parameter”.
Export limitation setting
7.
Exporlimit
OFF
ON
Meter
CT
Set OK
Set parameter
General
Advanced
Password
123
ExportLimit Rate
XXX.X%
Under the permission given by your energy provider, the ratio of your system output power divided by the rated power of the inverter is called
Export Limit Rate. For instance, if the energy provider only accepts 4kW from your 5KW system, then the Export Limit Rate of 5kW inverter is
80.0%.
GR
-
UM
-
193
-
A
-
01
AC Breaker
AC Breaker
Grid L
①
①
Note:
For Australian market, installers can connect pin3 or pin4 to the neutral links/bars.
①