  Specifications

Model 

MID 20KTL3-X MID 22KTL3-X MID 25KTL3-X

Input

 

data

(

DC

)

Max. recommended PV power(for 

module STC)

26000W

28600W

325000W

Max. DC voltage

1100V

Start voltage

250V

Nominal voltage

580V

MPP voltage range

160-1000V

Full-load voltage range

480-850V

520-850V

520-850V

No. of MPP trackers

2

No. of PV strings per MPP trackers

2

2

2/3

Max. input current per MPP trackers

25

25

25/37.5

Max. short-circuit current per MPP 
trackers

32

32

32/48

Output data(AC)

AC nominal power

20000W

22000W

25000W

Max. AC apparent 

22000VA

24400VA

27700VA

Nominal AC voltage/range

230V/400V

340-440V

AC grid frequency/range

50/60 Hz

45~55Hz/55-65 Hz

Max. output current

31.9A

35.5A

40.2A

Power factor(@nominal power)

>0.99

Adjustable power factor

0.8Leading ...0.8Lagging

THDi

<3%

AC grid connection type

3W+N+PE

Efficiency

Max. efficiency

98.65%

Euro-eta

98.3%

                                                 

                           

  Specifications

Model 

MID 20KTL3-X MID 22KTL3-X MID 25KTL3-X

Protection devices 

DC reverse-polarity protection

YES

DC switch

YES

DC Surge protection

typeII

Insulation resistance monitoring

YES

AC surge protection

typeII

AC short-circuit protection

YES

Grid monitoring

YES

Anti-islanding protection

YES

Residual-current monitoring unit

YES

String Fuse protection

YES

String monitoring

OPT

AFCI protection

OPT

General data 

Dimensions (W / H / D) in mm

525*395*222mm

Weight

23kg

Operating temperature range

-25°C ... +60°C

(>45°CDerating)

Noise emission (typical)

40dB(A)

Altitude

4000m

Internal consumption at night

1W

Topology

Transformerless

Cooling

Fan

 

cooling

Electronics protection degree

IP65

Relative humidity

0~100%

DC connection

H4/MC4(OPT)

AC connection

Cable gland+OT terminal

Interfaces

Display

OLED+LED/WIFI+APP

USB/RS485

YES

WIFI/GPRS/4G

OPT

38

Summary of Contents for MID 10KTL3-X

Page 1: ...nzhen P R China No 28 Guangming Road Shiyan Street Bao an District Shenzhen P R China 86 755 2747 1942 www ginverter com www ginverter com T E W service ginverter com service ginverter com 86 755 2747...

Page 2: ...2 1 Foreword 2 2 Applicable personnel 2 3 Product overview and features 2 4 Safety instructions 1 1 Validity 1 2 Target Group 1 3 Additional information 3 Product Description 4 Unpacking and Inspecti...

Page 3: ...ubleshooting 7 Debugging 14 Specification 8 1 Normal mode 8 2 Failure mode 8 3 Shutdown mode 9 1 Boot display 9 2 OLED display wake up 9 3 Touch operation 11 1 Start the inverter 11 2 Shut down the in...

Page 4: ...refully before using this product Any changes to this manual by Growatt New Energy will not be notified to the user 2 2 Applicable Personnel The inverter must be installed by a professional electricia...

Page 5: ...V modules Otherwise in the sunlight the voltage at the component terminals is high which poses a personal danger Make sure that the input DC voltage does not exceed 550V under any circumstances Higher...

Page 6: ...t operating state of the inverter red fault green normal operation Flashing red light warning Flashing green light Update program 3 2 Dimensions Size and weight Model Height H Width W Depth D Weight M...

Page 7: ...nverter for a long time refer to the specifications in Chapter 12 for the weight of the inverter The installation location must match the size of the inverter Do not install the inverter on a building...

Page 8: ...Installation Environment Make sure that the inverter is installed in a suitable place and is not allowed to be installed in a closed box fig5 4 Closed box In order to reduce the inverter load and ext...

Page 9: ...h of the inverter is in the OFF state and that the AC side is open otherwise the high voltage of the inverter may be life threatening Each inverter must be independently installed with an AC circuit b...

Page 10: ...er model Switch specification Inverter model Switch specification MID 6KTL3 XL 25A 127V MID 8KTL3 XL 32A 127V MID 10KTL3 XL 40A 127V MID 11KTL3 XL 40A 127V MID 12KTL3 XL 50A 127V MID 10KTL3 X 32A 230V...

Page 11: ...PV ground please turn on the low frequency isolation transformer after the output is connected otherwise the inverter will be damaged If it is measured that there is a stable non zero DC voltage betw...

Page 12: ...allation instructions 2 Push the threaded sleeve into the socket and tighten the waterproof gland fig6 9 Quick installation instructions Ka 3 Dock the client to the inverter plug until both are tightl...

Page 13: ...real time When the inverter monitors any unexpected conditions such as system failure and inverter failure the fault information will be displayed on the display In the fault mode the inverter indica...

Page 14: ...ic CT Off grid setting Enable Country Region VDE0126 Country Region VDE0126 Country Region G99 Country Region N4105 Country Region G98 Country Region Ireland Country Region EN50438 Country Region Belg...

Page 15: ...er 2 Close the DC switch when the input PV voltage is higher than 250Vdc and the inverter will start automatically Start and Shut Down the Inverter 11 11 1 Start the inverter 11 2 Shut down the invert...

Page 16: ...ew fan 5 Reinstall the fan mounting plate and inverter Troubleshooting 13 PV inverters sometimes do not work properly we recommend the following solutions to eliminate common faults The table below he...

Page 17: ...anufacturer 13 2 Syetem error 13 2 1 Warning code Warning Code Fault Discription Suggestion Warning 300 No Utility 1 Please confirm grid is lost or not 2 If error message still exists contact manufact...

Page 18: ...r 3 If error message still exists contact manufacturer Error Code Fault Discription Suggestion Error 300 AC V Outrange 1 Check grid voltage 2 If the error message still exists despite the grid voltage...

Page 19: ...art inverter 2 If error message still exists contact manufacturer Error 414 EEPROM fault 1 Restart inverter 2 If error message still exists contact manufacturer Error 415 Internal power test fail PV P...

Page 20: ...ctor 0 8Leading 0 8Lagging THDi 3 AC grid connection type 3W PE 3W N PE Efficiency Max efficiency 98 65 Euro eta 98 3 Specifications Model MID 6KTL3 XL MID 8KTL3 XL MID 10KTL3 XL MID 11KTL3 XL MID 12K...

Page 21: ...0 8Leading 0 8Lagging THDi 3 AC grid connection type 3W N PE Efficiency Max efficiency 98 65 Euro eta 98 3 Specifications Model MID 10KTL3 X MID 12KTL3 X MID 15KTL3 X MID 17KTL3 X Protection devices D...

Page 22: ...ng 0 8Lagging THDi 3 AC grid connection type 3W N PE Efficiency Max efficiency 98 65 Euro eta 98 3 Specifications Model MID 20KTL3 X MID 22KTL3 X MID 25KTL3 X Protection devices DC reverse polarity pr...

Page 23: ...ing the defective equipment The cost of installing or reinstalling a faulty device should also be explicitly excluded from other related logistics and processing costs associated with warranty claims...

Reviews: