2.4 Safety Instructions

1

Please read this manual carefully before installation. If the equipment is not installed 

according  to  the  instructions  in  this  manual,  or  if  the  equipment  in  the  manual  is 

ignored, the company has the right to not guarantee the quality; 
2

All  operations  and  wiring,  please  operate  by  professional  electrical  or  mechanical 

engineers; 
3

When  installing,  please  do  not  move  the  other  parts  inside  the  chassis  except  the 

terminal block; 
4

)

All electrical installations must comply with local electrical safety standards; 

5

If  the  machine  requires  maintenance,  please  contact  the  local  designated  system 

installation and maintenance personnel; 
6

The use of this machine for grid-connected power generation requires the permission 

of the local power supply department; 
7

When  installing  PV  modules  during  the  day,  use  opaque  materials  to  cover  the  PV 

modules.  Otherwise,  in  the  sunlight,  the  voltage  at  the  component  terminals  is  high, 

which poses a personal danger. 

 

Make  sure  that  the  input  DC  voltage  does  not  exceed  550V  under 

any circumstances. Higher input voltages may permanently damage 

the  machine  and  cause  other  damage,  in  which  case  the  company 

does not warrant and assumes any responsibility.

During  the  operation  of  the  machine,  the  surface  temperature  of 

the  outer  casing  is  high.  Please  carefully  touch  the  outer  casing  to 
prevent burns.

Danger

Warning

2.4.1 Sign convention

Sign

Explanation

High voltage danger

Plammable and explosive

High temperature

Wait 5 minutes after power off to ensure the machine is fully 

discharged

Safety ground

DC

AC

Read the manual carefully

2.3.2 Product  features

The characteristics of the inverter are as follows:

Ÿ

Dual independent maximum power point tracking

Ÿ

Built-in DC switch

Ÿ

Compatible with RS485/Wifi / GPRS / 4G communication

Ÿ

200V-1000V input voltage range

Ÿ

Maximum efficiency up to 98.65%

Ÿ

OLED display

Ÿ

Touch button

Ÿ

Protection level IP65

Ÿ

Weighs only 23kg

Ÿ

Easy installation

Summary of Contents for MID 10KTL3-X

Page 1: ...nzhen P R China No 28 Guangming Road Shiyan Street Bao an District Shenzhen P R China 86 755 2747 1942 www ginverter com www ginverter com T E W service ginverter com service ginverter com 86 755 2747...

Page 2: ...2 1 Foreword 2 2 Applicable personnel 2 3 Product overview and features 2 4 Safety instructions 1 1 Validity 1 2 Target Group 1 3 Additional information 3 Product Description 4 Unpacking and Inspecti...

Page 3: ...ubleshooting 7 Debugging 14 Specification 8 1 Normal mode 8 2 Failure mode 8 3 Shutdown mode 9 1 Boot display 9 2 OLED display wake up 9 3 Touch operation 11 1 Start the inverter 11 2 Shut down the in...

Page 4: ...refully before using this product Any changes to this manual by Growatt New Energy will not be notified to the user 2 2 Applicable Personnel The inverter must be installed by a professional electricia...

Page 5: ...V modules Otherwise in the sunlight the voltage at the component terminals is high which poses a personal danger Make sure that the input DC voltage does not exceed 550V under any circumstances Higher...

Page 6: ...t operating state of the inverter red fault green normal operation Flashing red light warning Flashing green light Update program 3 2 Dimensions Size and weight Model Height H Width W Depth D Weight M...

Page 7: ...nverter for a long time refer to the specifications in Chapter 12 for the weight of the inverter The installation location must match the size of the inverter Do not install the inverter on a building...

Page 8: ...Installation Environment Make sure that the inverter is installed in a suitable place and is not allowed to be installed in a closed box fig5 4 Closed box In order to reduce the inverter load and ext...

Page 9: ...h of the inverter is in the OFF state and that the AC side is open otherwise the high voltage of the inverter may be life threatening Each inverter must be independently installed with an AC circuit b...

Page 10: ...er model Switch specification Inverter model Switch specification MID 6KTL3 XL 25A 127V MID 8KTL3 XL 32A 127V MID 10KTL3 XL 40A 127V MID 11KTL3 XL 40A 127V MID 12KTL3 XL 50A 127V MID 10KTL3 X 32A 230V...

Page 11: ...PV ground please turn on the low frequency isolation transformer after the output is connected otherwise the inverter will be damaged If it is measured that there is a stable non zero DC voltage betw...

Page 12: ...allation instructions 2 Push the threaded sleeve into the socket and tighten the waterproof gland fig6 9 Quick installation instructions Ka 3 Dock the client to the inverter plug until both are tightl...

Page 13: ...real time When the inverter monitors any unexpected conditions such as system failure and inverter failure the fault information will be displayed on the display In the fault mode the inverter indica...

Page 14: ...ic CT Off grid setting Enable Country Region VDE0126 Country Region VDE0126 Country Region G99 Country Region N4105 Country Region G98 Country Region Ireland Country Region EN50438 Country Region Belg...

Page 15: ...er 2 Close the DC switch when the input PV voltage is higher than 250Vdc and the inverter will start automatically Start and Shut Down the Inverter 11 11 1 Start the inverter 11 2 Shut down the invert...

Page 16: ...ew fan 5 Reinstall the fan mounting plate and inverter Troubleshooting 13 PV inverters sometimes do not work properly we recommend the following solutions to eliminate common faults The table below he...

Page 17: ...anufacturer 13 2 Syetem error 13 2 1 Warning code Warning Code Fault Discription Suggestion Warning 300 No Utility 1 Please confirm grid is lost or not 2 If error message still exists contact manufact...

Page 18: ...r 3 If error message still exists contact manufacturer Error Code Fault Discription Suggestion Error 300 AC V Outrange 1 Check grid voltage 2 If the error message still exists despite the grid voltage...

Page 19: ...art inverter 2 If error message still exists contact manufacturer Error 414 EEPROM fault 1 Restart inverter 2 If error message still exists contact manufacturer Error 415 Internal power test fail PV P...

Page 20: ...ctor 0 8Leading 0 8Lagging THDi 3 AC grid connection type 3W PE 3W N PE Efficiency Max efficiency 98 65 Euro eta 98 3 Specifications Model MID 6KTL3 XL MID 8KTL3 XL MID 10KTL3 XL MID 11KTL3 XL MID 12K...

Page 21: ...0 8Leading 0 8Lagging THDi 3 AC grid connection type 3W N PE Efficiency Max efficiency 98 65 Euro eta 98 3 Specifications Model MID 10KTL3 X MID 12KTL3 X MID 15KTL3 X MID 17KTL3 X Protection devices D...

Page 22: ...ng 0 8Lagging THDi 3 AC grid connection type 3W N PE Efficiency Max efficiency 98 65 Euro eta 98 3 Specifications Model MID 20KTL3 X MID 22KTL3 X MID 25KTL3 X Protection devices DC reverse polarity pr...

Page 23: ...ing the defective equipment The cost of installing or reinstalling a faulty device should also be explicitly excluded from other related logistics and processing costs associated with warranty claims...

Reviews: